Coaxial Cable Manufacturers


HANGZHOU SANYUAN CABLE Co., Ltd is a professional Coaxial Cable Manufacturers and Coaxial Cable company.Our company produces diversified Coaxial Cable.The company has advanced production equipment and testing equipment. With the strong technical, human and material resources, perfect management system.
  • 21VAtC
    21VAtC

     

    CPR CLASS Eca

     

    1.- CABLE CONSTRUCTION
    Inner conductor Copper covered steel wire min. 21% 1,02+/- 0,01
    Elongation at break min 1%
    Tensile strength min. 380 N/mm2
    Adherence to dielectric min. 22 N
    Dielectric Gas injected foamed polyethylene  4,60 +/- 0,1 
    Shrinkage max 4 % after 4 hours at 115 ºC  
    Dielectric constant of base PE 2,25  
    Dielectric strength 1of PE 18 kV/mm  
    PE Oxidative Induction Time min. 30 minutes / ASTM D 4565 Chapter 17
    PE Oxidative Induction Time min. 70% after 14 days / 90 ºC
    First screen Tape Aluminium/Polyester/Aluminium 4,78 +/- 0,13 
    dielectric - Ovality max. 0,33
    Tape thickness0.009AL/0.012Pet/0.009AL  
    Overlapping min 18%
    Second screen Aluminum alloy braid 5,38 +/- 0,15
    Type 5154A or (5056, 5154, 5954)  
    Braid construction 16 x 5 x (0,12+0,01/-0,01)  min. 60%
    Elongation at break for every wire min 3%
    Tensile strength for every wire  300N/mm2
    Sheath PVC  - NO BAD ODORS 6,80 +/-0.15
    Sheath color WHITE  Thickness  0,80+/-0.10 mm
    Jacket thickness excentricity  max. 43 % 
    Tensile strength  min .11MPa(TM2)
    Tensile strength after 168 H at 80 ºc +/- 20% (TM2)
    Elongation at break  min. 150 %(TM2)
    Elongation at break after 168 H at 80 ºC +/- 20% (TM2)
    Spark test  min. 2,5 kVrms
    Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm

     

    2. Cable environmental characteristics
    Environmental Space Indoor | Outdoor  
    Working temperature                                -20 ºC +75 ºC  
    CPR Cable Classifications Euro Class Eca EN50575: 2014+ A1:2016
    Flame Test Listing                                                                      vertical flame IEC 60332-1-2
    UV Resistance per UL 1581, Paragraph 1200

    Percent Retention of Tensile Strength & 

    Elongation after 720 hours 

    exposure shall be ≥ 80.

    UL2556

     

    3- ELECTRICAL CHARACTERISTICS
    3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC
    Inner conductor resistance  Ohmios /km max. 102  
    Outer conductor resistance  Ohmios /km max. 37  
    Max. Loop current  Ampers 8 a 20 ºC - 6 a 40 ºC  
    Dielectric strength  2 kV D.C. or 1,5 kV A.C. for 1 min.  
    Insulation resistance  Mohm x km > 10000 Mohm x km  
    Mutual capacitance  53±2nF/km   
    Voltage test of sheath  2,5 kV A.C. or 3,75 kV D.C. for 1 min.  
    3.2 Electrical characteristics - High frecuency - @ 20 ºC
    Velocity of propagation  % 84±2  
    Characteristic impedance  Ohmios 75 +/- 3   
    Nominal Delay  nS/m max.  4,0  
    Transfer Impedance 5-30MHz ≤50mOhm/m IEC62153-4-3 
    Shielding Effectiveness 30-1000MHz ≥75dB IEC62153-4-4 
    1000-2000MHz ≥65dB
    2000-3000MHz ≥55dB
    Longitudinal attenuation MHz dB/100m  MAX  
    10 2.46   
    50 4.86   
    100 6.56   
    230 10.73   
    300 11.65   
    400 13.62   
    470 14.78   
    800 21.00   
    860 20.05   
    1000 21.49   
    1350 24.71   
    1750 28.67   
    2150 31.79   
    3000 37.53   
    Return Loss  5 MHz - 470MHz  ≥20dB  
     470 MHz - 1000MHz  ≥18dB  
     1000 MHz - 2000MHz  ≥16dB  
     2000 MHz - 3000MHz  ≥15dB  
    Read More
  • 23VAtC
    23VAtC

    CPR CLASS Eca

     

    1.- CABLE CONSTRUCTION
    Inner conductor Bare Copper 0,80+/- 0,01
    Elongation at break min 20%
    Adherence to dielectric 22 -89 N
    Dielectric Gas injected foamed polyethylene  3,50 +/- 0,1 
    Shrinkage max 4 % after 4 hours at 115 ºC  
    Dielectric constant of base PE 2,25  
    Dielectric strength 1of PE 18 kV/mm  
    PE Oxidative Induction Time min. 30 minutes / ASTM D 4565 Chapter 17
    PE Oxidative Induction Time min. 70% after 14 days / 90 ºC
    First screen Tape Aluminium/Polyester/Aluminium 3,73 +/- 0,13 
    dielectric - Ovality max. 0,28
    Tape thickness0.009AL/0.012Pet/0.009A  
    Overlapping min 18%
    Second screen CUSN braid 4,10 +/- 0,15
    Braid construction 52  x (0,10+0,01/-0,01)  min. 40%
    Elongation at break for every wire min 20%
    Tensile strength for every wire  150N/mm2
    Sheath PVC  - NO BAD ODORS 5,00 +/-0.15
    Sheath color WHITE  Thickness  0,50+/-0.05 mm
    Jacket thickness excentricity  max. 43 % 
    Tensile strength  min .11MPa(TM2)
    Tensile strength after 168 H at 80 ºc +/- 20%(TM2)
    Elongation at break  min. 150 %(TM2)
    Elongation at break after 168 H at 80 ºC +/- 20%(TM2)
    Spark test  min. 2,5 kVrms
    Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm

     

    2. Cable environmental characteristics
    Environmental Space Indoor | Outdoor  
    Working temperature                                -20 ºC +75 ºC  
    CPR Cable Classifications Euro Class Eca EN50575: 2014+ A1:2016
    Flame Test Listing                                                                      vertical flame IEC 60332-1-2
    UV Resistance per UL 1581, Paragraph 1200

    Percent Retention of Tensile Strength & 

    Elongation after 720 hours 

    exposure shall be ≥ 80.

    UL2556

     

    3- ELECTRICAL CHARACTERISTICS
    3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC
    Inner conductor resistance  Ohmios /km max. 37
    Outer conductor resistance  Ohmios /km max. 35
    Max. Loop current  Ampers 8 a 20 ºC - 6 a 40 ºC
    Dielectric strength  2 kV D.C. or 1,5 kV A.C. for 1 min.
    Insulation resistance  Mohm x km > 10000 Mohm x km
    Mutual capacitance  53±2nF/km 
    Voltage test of sheath  2,5 kV A.C. or 3,75 kV D.C. for 1 min.
    3.2 Electrical characteristics - High frecuency - @ 20 ºC
    Velocity of propagation  % 84±2  
    Characteristic impedance Ohmios 75 +/- 3   
    Nominal Delay nS/m max.  4,0  
    Transfer Impedance 5-30MHz ≤50mOhm/m IEC62153-4-3 
    Shielding Effectiveness 30-1000MHz ≥75dB IEC62153-4-4 
    1000-2000MHz ≥65dB
    2000-3000MHz ≥55dB
    Longitudinal attenuation MHz dB/100m  MAX  
    10 3.0   
    50 6.1   
    100 8.0   
    230 12.3   
    300 14.2   
    400 16.5   
    470 18.5   
    800 23.0   
    860 25.5   
    1000 26.8   
    1350 31.5   
    1750 36.4   
    2150 40.3   
    3000 48.0   
    Return Loss  5 MHz - 470MHz  ≥20dB  
     470 MHz - 1000MHz  ≥18dB  
     1000 MHz - 2000MHz  ≥16dB  
     2000 MHz - 3000MHz  ≥15dB  
    Read More
  • KX6 PVC
    KX6 PVC

    CPR CLASS Eca

     

    1.- CABLE CONSTRUCTION
    Inner conductor Bare Copper 7*0.20 +/-0.01
    Elongation at break min 20%
    Adherence to dielectric 22 -89 N
    Dielectric polyethylene  3.70 +/-0.05
    Dielectric constant of base PE 2,25  
    Dielectric strength 1of PE 18 kV/mm  
    PE Oxidative Induction Time min. 30 minutes / ASTM D 4565 Chapter 17
    PE Oxidative Induction Time min. 70% after 14 days / 90 ºC
    First screen Copper Clad Aluminium Wire Braid 4,05 +/- 0,15
    Braid construction 16 x 7x (0,12+0,003/-0,003)  min. 84%
    Elongation at break for every wire min 6%
    Tensile strength for every wire  190N/mm2
    Sheath PVC  - NO BAD ODORS 6.15 +/-0.20
    Sheath color BLACK RAL 9005 Thickness  0,8±0.1 mm
    Jacket thickness excentricity  max. 43 % 
    Tensile strength  min .11MPa(TM2)
    Tensile strength after 168 H at 80 ºc +/-20% (TM2)
    Elongation at break  min. 150 %(TM2)
    Elongation at break after 168 H at 80 ºC +/-20%(TM2)
    Bending test at low temperature -15°C
    Spark test  min. 2,5 kVrms
    Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm
    Sheath marking    
    Delivery form    

     

    2. Cable environmental characteristics
    Environmental Space Indoor | Outdoor  
    Working temperature                                -20 ºC +75 ºC  
    CPR Cable Classifications Euro Class Eca EN50575: 2014+ A1:2016
    Flame Test Listing                                                                      vertical flame IEC 60332-1-2
    UV Resistance per UL 1581, Paragraph 1200

    Percent Retention of Tensile Strength & 

    Elongation after 720 hours 

    exposure shall be ≥ 80.

    UL2556

     

    3.- ELECTRICAL CHARACTERISTICS
    3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC
    Inner conductor resistance  Ohmios /km max. 65
    Outer conductor resistance  Ohmios /km max. 42
    Max. Loop current  Ampers 8 a 20 ºC - 5 a 40 ºC
    Dielectric strength  2 kV D.C. or 1,5 kV A.C. for 1 min.
    Insulation resistance  Mohm x km > 5000 Mohm x km
    Mutual capacitance  67±2nF/km
    Voltage test of sheath  2,5 kV A.C. or 3,75 kV D.C. for 1 min.
    3.2 Electrical characteristics - High frecuency - @ 20 ºC
    Velocity of propagation  % 66
    Characteristic impedance Ohmios 75 +/- 3
    Nominal Delay nS/m max.  5,1
    MHz dB/100m  NOM
    50 8.5
    100 11.8
    200 16.5
    450 26
    800 35.8
    800 35.8
    1000 39.5
    Return Loss 5 MHz - 1000 MHz  min. 20dB
    Read More
  • KX6+2C OVERALL
    KX6+2C OVERALL

    CPR CLASS Eca

     

    1.- CABLE CONSTRUCTION
    Inner conductor Bare Copper 7*0.20 +/-0.01
    Elongation at break min 20%
    Adherence to dielectric 22 -89 N
    Dielectric polyethylene  3.70 +/-0.05
    Dielectric constant of base PE 2,25  
    Dielectric strength 1of PE 18 kV/mm  
    PE Oxidative Induction Time min. 30 minutes / ASTM D 4565 Chapter 17
    PE Oxidative Induction Time min. 70% after 14 days / 90 ºC
    First screen Copper Clad Aluminium Wire Braid 4,05 +/- 0,15
    Braid construction 16 x 7x (0,12+0,003/-0,003)  min. 84%
    Elongation at break for every wire min 6%
    Tensile strength for every wire  190N/mm2
    Inner Sheath PVC  - NO BAD ODORS 6.15 +/-0.20
    Sheath color BLACK RAL 9005 Thickness  0,8±0.1 mm
    Jacket thickness excentricity  max. 43 % 
    Tensile strength  min .11MPa (TM2)
    Tensile strength after 168 H at 80 ºc +/-20% (TM2)
    Elongation at break  min. 150 %(TM2)
    Elongation at break after 168 H at 80 ºC +/-20% (TM2)
    Bending test at low temperature -15°C
    Spark test  min. 2,5 kVrms
    Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm
    Power cord Bare Copper 24*0.20±0.02mm+1.80mm PVC BLACK 0.75mm2
    Bare Copper 24*0.20±0.01mm+ 1.80mm PVC RED 0.75mm2
    Outer Sheath PVC  - NO BAD ODORS 10.0 +/-0.30
    Sheath color BLACK RAL 9005 Thickness  1,0±0.2 mm
    Jacket thickness excentricity  max. 43 % 
    Tensile strength  min .11MPa  (TM2)
    Tensile strength after 168 H at 80 ºc +/-20%(TM2)
    Elongation at break  min. 150 %(TM2)
    Elongation at break after 168 H at 80 ºC +/-20% (TM2)
    Bending test at low temperature -15°C
    Spark test  min. 2,5 kVrms
    Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm

     

    2. Cable environmental characteristics
    Environmental Space Indoor | Outdoor  
    Working temperature                                -20 ºC +75 ºC  
    CPR Cable Classifications Euro Class Eca EN50575: 2014+ A1:2016
    Flame Test Listing                                                                      vertical flame IEC 60332-1-2
    UV Resistance per UL 1581, Paragraph 1200

    Percent Retention of Tensile Strength & 

    Elongation after 720 hours 

    exposure shall be ≥ 80.

    UL2556

     

    3.- ELECTRICAL CHARACTERISTICS
    3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC
    Inner conductor resistance  Ohmios /km max. 65
    Outer conductor resistance  Ohmios /km max. 42
    Max. Loop current  Ampers 8 a 20 ºC - 5 a 40 ºC
    Dielectric strength  2 kV D.C. or 1,5 kV A.C. for 1 min.
    Insulation resistance  Mohm x km > 5000 Mohm x km
    Mutual capacitance  67±2nF/km
    Voltage test of sheath  2,5 kV A.C. or 3,75 kV D.C. for 1 min.
    3.2 Electrical characteristics - High frecuency - @ 20 ºC
    Velocity of propagation  % 66
    Characteristic impedance Ohmios 75 +/- 3
    Nominal Delay nS/m max.  5,1
    MHz dB/100m  NOM
    50 8.5
    100 11.8
    200 16.5
    450 26
    800 35.8
    800 35.8
    1000 39.5
    Return Loss  5 MHz - 1000 MHz  min. 20dB
    Read More
  • KX6+2C PVC
    KX6+2C PVC

    CPR CLASS Eca

     

    1.- CABLE CONSTRUCTION
    Inner conductor Bare Copper 7*0.20 +/-0.01
    Elongation at break min 20%
    Adherence to dielectric 22 -89 N
    Dielectric polyethylene  3.70 +/-0.05
    Dielectric constant of base PE 2,25  
    Dielectric strength 1of PE 18 kV/mm  
    PE Oxidative Induction Time min. 30 minutes / ASTM D 4565 Chapter 17
    PE Oxidative Induction Time min. 70% after 14 days / 90 ºC
    First screen Copper Clad Aluminium Wire Braid 4,05 +/- 0,15
    Braid construction 16 x 7x (0,12+0,003/-0,003)  min. 84%
    Elongation at break for every wire min 6%
    Tensile strength for every wire  190N/mm2
    Power cord Bare Copper 24*0.20±0.02mm+1.80mm PVC BLACK 0.75mm2
    Bare Copper 24*0.20±0.01mm+ 1.80mm PVC RED 0.75mm2
    Power cord Out Sheath PVC  - NO BAD ODORS 4.80±3.0mm
    Sheath color GREEN RAL 6026 Thickness min. 0,5mm
    Jacket thickness excentricity  max. 43 % 
    Sheath PVC  - NO BAD ODORS 6.15 +/-0.20
    Sheath color GREEN RAL 6026 Thickness  0,8±0.1 mm
    Jacket thickness excentricity  max. 43 % 
    Tensile strength  min .11MPa  (TM2)
    Tensile strength after 168 H at 80 ºc +/-20% (TM2)
    Elongation at break  min. 150 %(TM2)
    Elongation at break after 168 H at 80 ºC +/-20%(TM2)
    Bending test at low temperature -15°C
    Spark test  min. 2,5 kVrms
    Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm

     

    2. Cable environmental characteristics
    Environmental Space Indoor | Outdoor  
    Working temperature                                -20 ºC +75 ºC  
    CPR Cable Classifications Euro Class Eca EN50575: 2014+ A1:2016
    Flame Test Listing                                                                      vertical flame IEC 60332-1-2
    UV Resistance per UL 1581, Paragraph 1200

    Percent Retention of Tensile Strength & 

    Elongation after 720 hours 

    exposure shall be ≥ 80.

    UL2556

     

    3.- ELECTRICAL CHARACTERISTICS
    3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC
    Inner conductor resistance  Ohmios /km max. 65
    Outer conductor resistance  Ohmios /km max. 42
    Max. Loop current  Ampers 8 a 20 ºC - 5 a 40 ºC
    Dielectric strength  2 kV D.C. or 1,5 kV A.C. for 1 min.
    Insulation resistance  Mohm x km > 5000 Mohm x km
    Mutual capacitance  67±2nF/km
    Voltage test of sheath  2,5 kV A.C. or 3,75 kV D.C. for 1 min.
    3.2 Electrical characteristics - High frecuency - @ 20 ºC
    Velocity of propagation  % 66
    Characteristic impedance Ohmios 75 +/- 3
    Nominal Delay nS/m max.  5,1
    MHz dB/100m  NOM
    50 8.5
    100 11.8
    200 16.5
    450 26
    800 35.8
    800 35.8
    1000 39.5
    Return Loss 5 MHz - 1000 MHz  min. 20dB
    Read More
  • KX1000
    KX1000

    CPR CLASS Eca

     

    1.- CABLE CONSTRUCTION
    Inner conductor Bare Copper 7*0.40+/- 0,01
    Elongation at break min 25%
    Adherence to dielectric min. 22 N
    Dielectric Gas injected foamed polyethylene  4,90 +/- 0,1 
    Shrinkage max 4 % after 4 hours at 115 ºC  
    Dielectric constant of base PE 2,25  
    Dielectric strength 1of PE 18 kV/mm  
    PE Oxidative Induction Time min. 30 minutes / ASTM D 4565 Chapter 17
    PE Oxidative Induction Time min. 70% after 14 days / 90 ºC
    First screen Tape Aluminium/Polyester/Aluminium + bonding layer 5,10 +/- 0,13 
    dielectric - Ovality max. 0,33
    Tape thickness0.009AL/0.012Pet/0.009AL/0.025EAA  
    Overlapping min 18%
    Second screen Annealed Tinned copper 5,38 +/- 0,15
    Braid construction 16 x 9 x (0,12+0,01/-0,01)  min. 90%
    Elongation at break for every wire min 25%
    Tensile strength for every wire  180N/mm2
    Sheath PVC  - NO BAD ODORS 7,00 +/-0.15
    Sheath color BLUE  Thickness  0,80+/-0.10 mm
    Jacket thickness excentricity  max. 43 % 
    Tensile strength  min .11MPa    (TM2)
    Tensile strength after 168 H at 80 ºc +/- 20% (TM2)
    Elongation at break  min. 150 %  (TM2)
    Elongation at break after 168 H at 80 ºC +/- 20%(TM2)
    Spark test  min. 2,5 kVrms
    Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm

     

    2. Cable environmental characteristics
    Environmental Space Indoor | Outdoor  
    Working temperature                                -20 ºC +75 ºC  
    CPR Cable Classifications Euro Class Eca EN50575: 2014+ A1:2016
    Flame Test Listing                                                                      vertical flame IEC 60332-1-2
    UV Resistance per UL 1581, Paragraph 1200

    Percent Retention of Tensile Strength & 

    Elongation after 720 hours 

    exposure shall be ≥ 80.

    UL2556

     

    3- ELECTRICAL CHARACTERISTICS
    3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC
    Inner conductor resistance  Ohmios /km max. 19.7
    Outer conductor resistance  Ohmios /km max. 11
    Max. Loop current  Ampers 8 a 20 ºC - 6 a 40 ºC
    Dielectric strength  2 kV D.C. or 1,5 kV A.C. for 1 min.
    Insulation resistance  Mohm x km > 10000 Mohm x km
    Mutual capacitance  53±2nF/km 
    Voltage test of sheath  2,5 kV A.C. or 3,75 kV D.C. for 1 min.
    3.2 Electrical characteristics - High frecuency - @ 20 ºC
    Velocity of propagation  % 84±2  
    Characteristic impedance Ohmios 75 +/- 3   
    Nominal Delay nS/m max.  4,0  
    Transfer Impedance 5-30MHz ≤5mOhm/m IEC62153-4-3 
    Shielding Effectiveness 30-1000MHz ≥85dB IEC62153-4-4 
    1000-2000MHz ≥75dB
    2000-3000MHz ≥65dB
    Longitudinal attenuation MHz dB/100m  MAX  
    5 1.60   
    10 2.21   
    50 4.60   
    100 6.40   
    200 9.30   
    500 15.40   
    800 20.50   
    1000 23.50   
    Return Loss 5 MHz - 470MHz  ≥20dB  
    470 MHz - 1000MHz  ≥18dB  
    Read More
  • RG59 PVC
    RG59 PVC

    CPR CLASS Eca

     

    1.- CABLE CONSTRUCTION
    Inner conductor Bare Copper 0,58+/- 0,01
    Elongation at break min 20%
    Adherence to dielectric 22 -89 N
    Dielectric polyethylene  3.70 +/-0.05
    Dielectric constant of base PE 2,25  
    Dielectric strength 1of PE 18 kV/mm  
    PE Oxidative Induction Time min. 30 minutes / ASTM D 4565 Chapter 17
    PE Oxidative Induction Time min. 70% after 14 days / 90 ºC
    First screen Copper Clad Aluminium Wire Braid 4,05 +/- 0,15
    Braid construction 16 x 7x (0,12+0,003/-0,003)  min. 84%
    Elongation at break for every wire min 6%
    Tensile strength for every wire  190N/mm2
    Sheath PVC  - NO BAD ODORS 6.15 +/-0.20
    Sheath color BLACK RAL 9005 Thickness  0,8±0.1 mm
    Jacket thickness excentricity  max. 43 % 
    Tensile strength  min .11MPa (TM2)
    Tensile strength after 168 H at 80 ºc +/-20%(TM2)
    Elongation at break  min. 150 %(TM2)
    Elongation at break after 168 H at 80 ºC +/-20% (TM2)
    Bending test at low temperature -15°C
    Spark test  min. 2,5 kVrms
    Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm
    Sheath marking    
    Delivery form    

     

    2. Cable environmental characteristics
    Environmental Space Indoor | Outdoor  
    Working temperature                                -20 ºC +75 ºC  
    CPR Cable Classifications Euro Class Eca EN50575: 2014+ A1:2016
    Flame Test Listing                                                                      vertical flame IEC 60332-1-2
    UV Resistance per UL 1581, Paragraph 1200

    Percent Retention of Tensile Strength &

    Elongation after 720 hours 

    exposure shall be ≥ 80.

    UL2556

     

    3.- ELECTRICAL CHARACTERISTICS
    3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC
    Inner conductor resistance  Ohmios /km max. 65
    Outer conductor resistance  Ohmios /km max. 42
    Max. Loop current  Ampers 8 a 20 ºC - 5 a 40 ºC
    Dielectric strength  2 kV D.C. or 1,5 kV A.C. for 1 min.
    Insulation resistance  Mohm x km > 5000 Mohm x km
    Mutual capacitance  67±2nF/km
    Voltage test of sheath  2,5 kV A.C. or 3,75 kV D.C. for 1 min.
    3.2 Electrical characteristics - High frecuency - @ 20 ºC
    Velocity of propagation  % 66
    Characteristic impedance Ohmios 75 +/- 3
    Nominal Delay nS/m max.  5,1
    MHz dB/100m  NOM
    50 8.5
    100 11.8
    200 16.5
    450 26
    800 35.8
    800 35.8
    1000 39.5
    Return Loss 5 MHz - 1000 MHz  min. 20dB
    Read More
  • RG59+2C PVC
    RG59+2C PVC

    CPR CLASS Eca

     

    1.- CABLE CONSTRUCTION
    Inner conductor Bare Copper 0.58 +/-0.01
    Elongation at break min 20%
    Adherence to dielectric 22 -89 N
    Dielectric polyethylene  3.70 +/-0.05
    Dielectric constant of base PE 2,25  
    Dielectric strength 1of PE 18 kV/mm  
    PE Oxidative Induction Time min. 30 minutes / ASTM D 4565 Chapter 17
    PE Oxidative Induction Time min. 70% after 14 days / 90 ºC
    First screen Copper Clad Aluminium Wire Braid 4,05 +/- 0,15
    Braid construction 16 x 7x (0,12+0,003/-0,003)  min. 84%
    Elongation at break for every wire min 6%
    Tensile strength for every wire  190N/mm2
    Power cord Bare Copper 24*0.20±0.02mm+1.80mm PVC BLACK 0.75mm2
    Bare Copper 24*0.20±0.01mm+ 1.80mm PVC RED 0.75mm2
    Power cord Out Sheath PVC  - NO BAD ODORS 4.80±3.0mm
    Sheath color BLACK RAL 9005 Thickness min. 0,5mm
    Jacket thickness excentricity  max. 43 % 
    Sheath PVC  - NO BAD ODORS 6.15 +/-0.20
    Sheath color BLACK RAL 9005 Thickness  0,8±0.1 mm
    Jacket thickness excentricity  max. 43 % 
    Tensile strength  min .11MPa(TM2)
    Tensile strength after 168 H at 80 ºc +/-20% (TM2)
    Elongation at break  min. 150 %(TM2)
    Elongation at break after 168 H at 80 ºC +/-20%(TM2)
    Bending test at low temperature -15°C
    Spark test  min. 2,5 kVrms
    Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm

     

    2. Cable environmental characteristics
    Environmental Space Indoor | Outdoor  
    Working temperature                                -20 ºC +75 ºC  
    CPR Cable Classifications Euro Class Eca EN50575: 2014+ A1:2016
    Flame Test Listing                                                                      vertical flame IEC 60332-1-2
    UV Resistance per UL 1581, Paragraph 1200

    Percent Retention of Tensile Strength & 

    Elongation after 720 hours 

    exposure shall be ≥ 80.

    UL2556

     

    3.- ELECTRICAL CHARACTERISTICS
    3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC
    Inner conductor resistance  Ohmios /km max. 65
    Outer conductor resistance  Ohmios /km max. 42
    Max. Loop current  Ampers 8 a 20 ºC - 5 a 40 ºC
    Dielectric strength  2 kV D.C. or 1,5 kV A.C. for 1 min.
    Insulation resistance  Mohm x km > 5000 Mohm x km
    Mutual capacitance  67±2nF/km
    Voltage test of sheath  2,5 kV A.C. or 3,75 kV D.C. for 1 min.
    3.2 Electrical characteristics - High frecuency - @ 20 ºC
    Velocity of propagation  % 66
    Characteristic impedance Ohmios 75 +/- 3
    Nominal Delay nS/m max.  5,1
    MHz dB/100m  NOM
    50 8.5
    100 11.8
    200 16.5
    450 26
    800 35.8
    800 35.8
    1000 39.5
    Return Loss 5 MHz - 1000 MHz  min. 20dB
    Read More
1234