Coaxial Cable 75 Ohm Suppliers Any Questions?Call us:+86 571 63761139
Home / Products / Coaxial Cable / 75 Ohm (Page 4)
SEARCH HERE
Contact Us
1.- CABLE CONSTRUCTION | |||
Inner conductor | Copper covered steel wire min. 21% | 1,02+/- 0,01 | |
Elongation at break | min 1% | ||
Tensile strength | min. 380 N/mm2 | ||
Adherence to dielectric | min. 22 N | ||
Dielectric | Gas injected foamed polyethylene | 4,60 +/- 0,1 | |
Shrinkage max 4 % after 4 hours at 115 ºC | |||
Dielectric constant of base PE 2,25 | |||
Dielectric strength 1of PE 18 kV/mm | |||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | ||
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | ||
First screen | Tape Aluminium/Polyester/Aluminium | 4,78 +/- 0,13 | |
dielectric - Ovality | max. 0,33 | ||
Tape thickness0.009AL/0.012Pet/0.009AL | |||
Overlapping | min 18% | ||
Second screen | Aluminum alloy braid | 5,38 +/- 0,15 | |
Type 5154A or (5056, 5154, 5954) | |||
Braid construction 16 x 5 x (0,12+0,01/-0,01) | min. 60% | ||
Elongation at break for every wire | min 3% | ||
Tensile strength for every wire | 300N/mm2 | ||
Sheath | PVC - NO BAD ODORS | 6,80 +/-0.15 | |
Sheath color WHITE | Thickness 0,80+/-0.10 mm | ||
Jacket thickness excentricity | max. 43 % | ||
Tensile strength | min .11MPa(TM2) | ||
Tensile strength after 168 H at 80 ºc | +/- 20% (TM2) | ||
Elongation at break | min. 150 %(TM2) | ||
Elongation at break after 168 H at 80 ºC | +/- 20% (TM2) | ||
Spark test | min. 2,5 kVrms | ||
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2. Cable environmental characteristics | ||||
Environmental Space | Indoor | Outdoor | |||
Working temperature | -20 ºC +75 ºC | |||
CPR Cable Classifications | Euro Class Eca | EN50575: 2014+ A1:2016 | ||
Flame Test Listing | vertical flame | IEC 60332-1-2 | ||
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3- ELECTRICAL CHARACTERISTICS | ||||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | ||||
Inner conductor resistance | Ohmios /km max. 102 | |||
Outer conductor resistance | Ohmios /km max. 37 | |||
Max. Loop current | Ampers 8 a 20 ºC - 6 a 40 ºC | |||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | |||
Insulation resistance | Mohm x km > 10000 Mohm x km | |||
Mutual capacitance | 53±2nF/km | |||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | |||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | ||||
Velocity of propagation | % | 84±2 | ||
Characteristic impedance | Ohmios | 75 +/- 3 | ||
Nominal Delay | nS/m max. | 4,0 | ||
Transfer Impedance | 5-30MHz | ≤50mOhm/m | IEC62153-4-3 | |
Shielding Effectiveness | 30-1000MHz | ≥75dB | IEC62153-4-4 | |
1000-2000MHz | ≥65dB | |||
2000-3000MHz | ≥55dB | |||
Longitudinal attenuation | MHz | dB/100m MAX | ||
10 | 2.46 | |||
50 | 4.86 | |||
100 | 6.56 | |||
230 | 10.73 | |||
300 | 11.65 | |||
400 | 13.62 | |||
470 | 14.78 | |||
800 | 21.00 | |||
860 | 20.05 | |||
1000 | 21.49 | |||
1350 | 24.71 | |||
1750 | 28.67 | |||
2150 | 31.79 | |||
3000 | 37.53 | |||
Return Loss | 5 MHz - 470MHz | ≥20dB | ||
470 MHz - 1000MHz | ≥18dB | |||
1000 MHz - 2000MHz | ≥16dB | |||
2000 MHz - 3000MHz | ≥15dB |
1.- CABLE CONSTRUCTION | |||
Inner conductor | Bare Copper | 0,80+/- 0,01 | |
Elongation at break | min 20% | ||
Adherence to dielectric | 22 -89 N | ||
Dielectric | Gas injected foamed polyethylene | 3,50 +/- 0,1 | |
Shrinkage max 4 % after 4 hours at 115 ºC | |||
Dielectric constant of base PE 2,25 | |||
Dielectric strength 1of PE 18 kV/mm | |||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | ||
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | ||
First screen | Tape Aluminium/Polyester/Aluminium | 3,73 +/- 0,13 | |
dielectric - Ovality | max. 0,28 | ||
Tape thickness0.009AL/0.012Pet/0.009A | |||
Overlapping | min 18% | ||
Second screen | CUSN braid | 4,10 +/- 0,15 | |
Braid construction 52 x (0,10+0,01/-0,01) | min. 40% | ||
Elongation at break for every wire | min 20% | ||
Tensile strength for every wire | 150N/mm2 | ||
Sheath | PVC - NO BAD ODORS | 5,00 +/-0.15 | |
Sheath color WHITE | Thickness 0,50+/-0.05 mm | ||
Jacket thickness excentricity | max. 43 % | ||
Tensile strength | min .11MPa(TM2) | ||
Tensile strength after 168 H at 80 ºc | +/- 20%(TM2) | ||
Elongation at break | min. 150 %(TM2) | ||
Elongation at break after 168 H at 80 ºC | +/- 20%(TM2) | ||
Spark test | min. 2,5 kVrms | ||
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2. Cable environmental characteristics | ||||
Environmental Space | Indoor | Outdoor | |||
Working temperature | -20 ºC +75 ºC | |||
CPR Cable Classifications | Euro Class Eca | EN50575: 2014+ A1:2016 | ||
Flame Test Listing | vertical flame | IEC 60332-1-2 | ||
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3- ELECTRICAL CHARACTERISTICS | ||||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | ||||
Inner conductor resistance | Ohmios /km max. 37 | |||
Outer conductor resistance | Ohmios /km max. 35 | |||
Max. Loop current | Ampers 8 a 20 ºC - 6 a 40 ºC | |||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | |||
Insulation resistance | Mohm x km > 10000 Mohm x km | |||
Mutual capacitance | 53±2nF/km | |||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | |||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | ||||
Velocity of propagation | % | 84±2 | ||
Characteristic impedance | Ohmios | 75 +/- 3 | ||
Nominal Delay | nS/m max. | 4,0 | ||
Transfer Impedance | 5-30MHz | ≤50mOhm/m | IEC62153-4-3 | |
Shielding Effectiveness | 30-1000MHz | ≥75dB | IEC62153-4-4 | |
1000-2000MHz | ≥65dB | |||
2000-3000MHz | ≥55dB | |||
Longitudinal attenuation | MHz | dB/100m MAX | ||
10 | 3.0 | |||
50 | 6.1 | |||
100 | 8.0 | |||
230 | 12.3 | |||
300 | 14.2 | |||
400 | 16.5 | |||
470 | 18.5 | |||
800 | 23.0 | |||
860 | 25.5 | |||
1000 | 26.8 | |||
1350 | 31.5 | |||
1750 | 36.4 | |||
2150 | 40.3 | |||
3000 | 48.0 | |||
Return Loss | 5 MHz - 470MHz | ≥20dB | ||
470 MHz - 1000MHz | ≥18dB | |||
1000 MHz - 2000MHz | ≥16dB | |||
2000 MHz - 3000MHz | ≥15dB |
1.- CABLE CONSTRUCTION | ||
Inner conductor | Bare Copper | 7*0.20 +/-0.01 |
Elongation at break | min 20% | |
Adherence to dielectric | 22 -89 N | |
Dielectric | polyethylene | 3.70 +/-0.05 |
Dielectric constant of base PE 2,25 | ||
Dielectric strength 1of PE 18 kV/mm | ||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | |
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | |
First screen | Copper Clad Aluminium Wire Braid | 4,05 +/- 0,15 |
Braid construction 16 x 7x (0,12+0,003/-0,003) | min. 84% | |
Elongation at break for every wire | min 6% | |
Tensile strength for every wire | 190N/mm2 | |
Sheath | PVC - NO BAD ODORS | 6.15 +/-0.20 |
Sheath color BLACK RAL 9005 | Thickness 0,8±0.1 mm | |
Jacket thickness excentricity | max. 43 % | |
Tensile strength | min .11MPa(TM2) | |
Tensile strength after 168 H at 80 ºc | +/-20% (TM2) | |
Elongation at break | min. 150 %(TM2) | |
Elongation at break after 168 H at 80 ºC | +/-20%(TM2) | |
Bending test at low temperature | -15°C | |
Spark test | min. 2,5 kVrms | |
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm | |
Sheath marking | ||
Delivery form |
2. Cable environmental characteristics | |||
Environmental Space | Indoor | Outdoor | ||
Working temperature | -20 ºC +75 ºC | ||
CPR Cable Classifications | Euro Class Eca | EN50575: 2014+ A1:2016 | |
Flame Test Listing | vertical flame | IEC 60332-1-2 | |
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3.- ELECTRICAL CHARACTERISTICS | |||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | |||
Inner conductor resistance | Ohmios /km max. 65 | ||
Outer conductor resistance | Ohmios /km max. 42 | ||
Max. Loop current | Ampers 8 a 20 ºC - 5 a 40 ºC | ||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | ||
Insulation resistance | Mohm x km > 5000 Mohm x km | ||
Mutual capacitance | 67±2nF/km | ||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | ||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | |||
Velocity of propagation | % | 66 | |
Characteristic impedance | Ohmios | 75 +/- 3 | |
Nominal Delay | nS/m max. | 5,1 | |
MHz | dB/100m NOM | ||
50 | 8.5 | ||
100 | 11.8 | ||
200 | 16.5 | ||
450 | 26 | ||
800 | 35.8 | ||
800 | 35.8 | ||
1000 | 39.5 | ||
Return Loss | 5 MHz - 1000 MHz | min. 20dB |
1.- CABLE CONSTRUCTION | ||
Inner conductor | Bare Copper | 7*0.20 +/-0.01 |
Elongation at break | min 20% | |
Adherence to dielectric | 22 -89 N | |
Dielectric | polyethylene | 3.70 +/-0.05 |
Dielectric constant of base PE 2,25 | ||
Dielectric strength 1of PE 18 kV/mm | ||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | |
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | |
First screen | Copper Clad Aluminium Wire Braid | 4,05 +/- 0,15 |
Braid construction 16 x 7x (0,12+0,003/-0,003) | min. 84% | |
Elongation at break for every wire | min 6% | |
Tensile strength for every wire | 190N/mm2 | |
Inner Sheath | PVC - NO BAD ODORS | 6.15 +/-0.20 |
Sheath color BLACK RAL 9005 | Thickness 0,8±0.1 mm | |
Jacket thickness excentricity | max. 43 % | |
Tensile strength | min .11MPa (TM2) | |
Tensile strength after 168 H at 80 ºc | +/-20% (TM2) | |
Elongation at break | min. 150 %(TM2) | |
Elongation at break after 168 H at 80 ºC | +/-20% (TM2) | |
Bending test at low temperature | -15°C | |
Spark test | min. 2,5 kVrms | |
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm | |
Power cord | Bare Copper 24*0.20±0.02mm+1.80mm PVC BLACK | 0.75mm2 |
Bare Copper 24*0.20±0.01mm+ 1.80mm PVC RED | 0.75mm2 | |
Outer Sheath | PVC - NO BAD ODORS | 10.0 +/-0.30 |
Sheath color BLACK RAL 9005 | Thickness 1,0±0.2 mm | |
Jacket thickness excentricity | max. 43 % | |
Tensile strength | min .11MPa (TM2) | |
Tensile strength after 168 H at 80 ºc | +/-20%(TM2) | |
Elongation at break | min. 150 %(TM2) | |
Elongation at break after 168 H at 80 ºC | +/-20% (TM2) | |
Bending test at low temperature | -15°C | |
Spark test | min. 2,5 kVrms | |
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2. Cable environmental characteristics | |||
Environmental Space | Indoor | Outdoor | ||
Working temperature | -20 ºC +75 ºC | ||
CPR Cable Classifications | Euro Class Eca | EN50575: 2014+ A1:2016 | |
Flame Test Listing | vertical flame | IEC 60332-1-2 | |
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3.- ELECTRICAL CHARACTERISTICS | |||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | |||
Inner conductor resistance | Ohmios /km max. 65 | ||
Outer conductor resistance | Ohmios /km max. 42 | ||
Max. Loop current | Ampers 8 a 20 ºC - 5 a 40 ºC | ||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | ||
Insulation resistance | Mohm x km > 5000 Mohm x km | ||
Mutual capacitance | 67±2nF/km | ||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | ||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | |||
Velocity of propagation | % | 66 | |
Characteristic impedance | Ohmios | 75 +/- 3 | |
Nominal Delay | nS/m max. | 5,1 | |
MHz | dB/100m NOM | ||
50 | 8.5 | ||
100 | 11.8 | ||
200 | 16.5 | ||
450 | 26 | ||
800 | 35.8 | ||
800 | 35.8 | ||
1000 | 39.5 | ||
Return Loss | 5 MHz - 1000 MHz | min. 20dB |
1.- CABLE CONSTRUCTION | ||
Inner conductor | Bare Copper | 7*0.20 +/-0.01 |
Elongation at break | min 20% | |
Adherence to dielectric | 22 -89 N | |
Dielectric | polyethylene | 3.70 +/-0.05 |
Dielectric constant of base PE 2,25 | ||
Dielectric strength 1of PE 18 kV/mm | ||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | |
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | |
First screen | Copper Clad Aluminium Wire Braid | 4,05 +/- 0,15 |
Braid construction 16 x 7x (0,12+0,003/-0,003) | min. 84% | |
Elongation at break for every wire | min 6% | |
Tensile strength for every wire | 190N/mm2 | |
Power cord | Bare Copper 24*0.20±0.02mm+1.80mm PVC BLACK | 0.75mm2 |
Bare Copper 24*0.20±0.01mm+ 1.80mm PVC RED | 0.75mm2 | |
Power cord Out Sheath | PVC - NO BAD ODORS | 4.80±3.0mm |
Sheath color GREEN RAL 6026 | Thickness min. 0,5mm | |
Jacket thickness excentricity | max. 43 % | |
Sheath | PVC - NO BAD ODORS | 6.15 +/-0.20 |
Sheath color GREEN RAL 6026 | Thickness 0,8±0.1 mm | |
Jacket thickness excentricity | max. 43 % | |
Tensile strength | min .11MPa (TM2) | |
Tensile strength after 168 H at 80 ºc | +/-20% (TM2) | |
Elongation at break | min. 150 %(TM2) | |
Elongation at break after 168 H at 80 ºC | +/-20%(TM2) | |
Bending test at low temperature | -15°C | |
Spark test | min. 2,5 kVrms | |
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2. Cable environmental characteristics | |||
Environmental Space | Indoor | Outdoor | ||
Working temperature | -20 ºC +75 ºC | ||
CPR Cable Classifications | Euro Class Eca | EN50575: 2014+ A1:2016 | |
Flame Test Listing | vertical flame | IEC 60332-1-2 | |
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3.- ELECTRICAL CHARACTERISTICS | |||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | |||
Inner conductor resistance | Ohmios /km max. 65 | ||
Outer conductor resistance | Ohmios /km max. 42 | ||
Max. Loop current | Ampers 8 a 20 ºC - 5 a 40 ºC | ||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | ||
Insulation resistance | Mohm x km > 5000 Mohm x km | ||
Mutual capacitance | 67±2nF/km | ||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | ||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | |||
Velocity of propagation | % | 66 | |
Characteristic impedance | Ohmios | 75 +/- 3 | |
Nominal Delay | nS/m max. | 5,1 | |
MHz | dB/100m NOM | ||
50 | 8.5 | ||
100 | 11.8 | ||
200 | 16.5 | ||
450 | 26 | ||
800 | 35.8 | ||
800 | 35.8 | ||
1000 | 39.5 | ||
Return Loss | 5 MHz - 1000 MHz | min. 20dB |
1.- CABLE CONSTRUCTION | ||
Inner conductor | Bare Copper | 7*0.40+/- 0,01 |
Elongation at break | min 25% | |
Adherence to dielectric | min. 22 N | |
Dielectric | Gas injected foamed polyethylene | 4,90 +/- 0,1 |
Shrinkage max 4 % after 4 hours at 115 ºC | ||
Dielectric constant of base PE 2,25 | ||
Dielectric strength 1of PE 18 kV/mm | ||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | |
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | |
First screen | Tape Aluminium/Polyester/Aluminium + bonding layer | 5,10 +/- 0,13 |
dielectric - Ovality | max. 0,33 | |
Tape thickness0.009AL/0.012Pet/0.009AL/0.025EAA | ||
Overlapping | min 18% | |
Second screen | Annealed Tinned copper | 5,38 +/- 0,15 |
Braid construction 16 x 9 x (0,12+0,01/-0,01) | min. 90% | |
Elongation at break for every wire | min 25% | |
Tensile strength for every wire | 180N/mm2 | |
Sheath | PVC - NO BAD ODORS | 7,00 +/-0.15 |
Sheath color BLUE | Thickness 0,80+/-0.10 mm | |
Jacket thickness excentricity | max. 43 % | |
Tensile strength | min .11MPa (TM2) | |
Tensile strength after 168 H at 80 ºc | +/- 20% (TM2) | |
Elongation at break | min. 150 % (TM2) | |
Elongation at break after 168 H at 80 ºC | +/- 20%(TM2) | |
Spark test | min. 2,5 kVrms | |
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2. Cable environmental characteristics | ||
Environmental Space | Indoor | Outdoor | |
Working temperature | -20 ºC +75 ºC | |
CPR Cable Classifications | Euro Class Eca | EN50575: 2014+ A1:2016 |
Flame Test Listing | vertical flame | IEC 60332-1-2 |
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3- ELECTRICAL CHARACTERISTICS | ||||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | ||||
Inner conductor resistance | Ohmios /km max. 19.7 | |||
Outer conductor resistance | Ohmios /km max. 11 | |||
Max. Loop current | Ampers 8 a 20 ºC - 6 a 40 ºC | |||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | |||
Insulation resistance | Mohm x km > 10000 Mohm x km | |||
Mutual capacitance | 53±2nF/km | |||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | |||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | ||||
Velocity of propagation | % | 84±2 | ||
Characteristic impedance | Ohmios | 75 +/- 3 | ||
Nominal Delay | nS/m max. | 4,0 | ||
Transfer Impedance | 5-30MHz | ≤5mOhm/m | IEC62153-4-3 | |
Shielding Effectiveness | 30-1000MHz | ≥85dB | IEC62153-4-4 | |
1000-2000MHz | ≥75dB | |||
2000-3000MHz | ≥65dB | |||
Longitudinal attenuation | MHz | dB/100m MAX | ||
5 | 1.60 | |||
10 | 2.21 | |||
50 | 4.60 | |||
100 | 6.40 | |||
200 | 9.30 | |||
500 | 15.40 | |||
800 | 20.50 | |||
1000 | 23.50 | |||
Return Loss | 5 MHz - 470MHz | ≥20dB | ||
470 MHz - 1000MHz | ≥18dB |
1.- CABLE CONSTRUCTION | ||
Inner conductor | Bare Copper | 0,58+/- 0,01 |
Elongation at break | min 20% | |
Adherence to dielectric | 22 -89 N | |
Dielectric | polyethylene | 3.70 +/-0.05 |
Dielectric constant of base PE 2,25 | ||
Dielectric strength 1of PE 18 kV/mm | ||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | |
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | |
First screen | Copper Clad Aluminium Wire Braid | 4,05 +/- 0,15 |
Braid construction 16 x 7x (0,12+0,003/-0,003) | min. 84% | |
Elongation at break for every wire | min 6% | |
Tensile strength for every wire | 190N/mm2 | |
Sheath | PVC - NO BAD ODORS | 6.15 +/-0.20 |
Sheath color BLACK RAL 9005 | Thickness 0,8±0.1 mm | |
Jacket thickness excentricity | max. 43 % | |
Tensile strength | min .11MPa (TM2) | |
Tensile strength after 168 H at 80 ºc | +/-20%(TM2) | |
Elongation at break | min. 150 %(TM2) | |
Elongation at break after 168 H at 80 ºC | +/-20% (TM2) | |
Bending test at low temperature | -15°C | |
Spark test | min. 2,5 kVrms | |
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm | |
Sheath marking | ||
Delivery form |
2. Cable environmental characteristics | |||
Environmental Space | Indoor | Outdoor | ||
Working temperature | -20 ºC +75 ºC | ||
CPR Cable Classifications | Euro Class Eca | EN50575: 2014+ A1:2016 | |
Flame Test Listing | vertical flame | IEC 60332-1-2 | |
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3.- ELECTRICAL CHARACTERISTICS | |||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | |||
Inner conductor resistance | Ohmios /km max. 65 | ||
Outer conductor resistance | Ohmios /km max. 42 | ||
Max. Loop current | Ampers 8 a 20 ºC - 5 a 40 ºC | ||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | ||
Insulation resistance | Mohm x km > 5000 Mohm x km | ||
Mutual capacitance | 67±2nF/km | ||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | ||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | |||
Velocity of propagation | % | 66 | |
Characteristic impedance | Ohmios | 75 +/- 3 | |
Nominal Delay | nS/m max. | 5,1 | |
MHz | dB/100m NOM | ||
50 | 8.5 | ||
100 | 11.8 | ||
200 | 16.5 | ||
450 | 26 | ||
800 | 35.8 | ||
800 | 35.8 | ||
1000 | 39.5 | ||
Return Loss | 5 MHz - 1000 MHz | min. 20dB |
1.- CABLE CONSTRUCTION | ||
Inner conductor | Bare Copper | 0.58 +/-0.01 |
Elongation at break | min 20% | |
Adherence to dielectric | 22 -89 N | |
Dielectric | polyethylene | 3.70 +/-0.05 |
Dielectric constant of base PE 2,25 | ||
Dielectric strength 1of PE 18 kV/mm | ||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | |
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | |
First screen | Copper Clad Aluminium Wire Braid | 4,05 +/- 0,15 |
Braid construction 16 x 7x (0,12+0,003/-0,003) | min. 84% | |
Elongation at break for every wire | min 6% | |
Tensile strength for every wire | 190N/mm2 | |
Power cord | Bare Copper 24*0.20±0.02mm+1.80mm PVC BLACK | 0.75mm2 |
Bare Copper 24*0.20±0.01mm+ 1.80mm PVC RED | 0.75mm2 | |
Power cord Out Sheath | PVC - NO BAD ODORS | 4.80±3.0mm |
Sheath color BLACK RAL 9005 | Thickness min. 0,5mm | |
Jacket thickness excentricity | max. 43 % | |
Sheath | PVC - NO BAD ODORS | 6.15 +/-0.20 |
Sheath color BLACK RAL 9005 | Thickness 0,8±0.1 mm | |
Jacket thickness excentricity | max. 43 % | |
Tensile strength | min .11MPa(TM2) | |
Tensile strength after 168 H at 80 ºc | +/-20% (TM2) | |
Elongation at break | min. 150 %(TM2) | |
Elongation at break after 168 H at 80 ºC | +/-20%(TM2) | |
Bending test at low temperature | -15°C | |
Spark test | min. 2,5 kVrms | |
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2. Cable environmental characteristics | |||
Environmental Space | Indoor | Outdoor | ||
Working temperature | -20 ºC +75 ºC | ||
CPR Cable Classifications | Euro Class Eca | EN50575: 2014+ A1:2016 | |
Flame Test Listing | vertical flame | IEC 60332-1-2 | |
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3.- ELECTRICAL CHARACTERISTICS | |||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | |||
Inner conductor resistance | Ohmios /km max. 65 | ||
Outer conductor resistance | Ohmios /km max. 42 | ||
Max. Loop current | Ampers 8 a 20 ºC - 5 a 40 ºC | ||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | ||
Insulation resistance | Mohm x km > 5000 Mohm x km | ||
Mutual capacitance | 67±2nF/km | ||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | ||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | |||
Velocity of propagation | % | 66 | |
Characteristic impedance | Ohmios | 75 +/- 3 | |
Nominal Delay | nS/m max. | 5,1 | |
MHz | dB/100m NOM | ||
50 | 8.5 | ||
100 | 11.8 | ||
200 | 16.5 | ||
450 | 26 | ||
800 | 35.8 | ||
800 | 35.8 | ||
1000 | 39.5 | ||
Return Loss | 5 MHz - 1000 MHz | min. 20dB |
Certifications
Product List
Contact Us
Add:No.1058 Jinxi Road,Linglong Industial Zone ,Lin'an City, Zhejiang Province,China.
Tel:+86 571 63761139
Fax:+86 571 63929811
E-mail: amanda@sanyuancable.com.cn
Mobile Phone Version
Sweep into the mobile version
Copyright © 2017 HANGZHOU SANYUAN CABLE CO., LTD. All Rights Reserved Design by: HWAQ