HANGZHOU SANYUAN CABLE Co., Ltd is a professional Coaxial Cable 75 Ohm european Standard Manufacturers and Coaxial Cable 75 Ohm european Standard company.Our company produces diversified European Standard.The company has advanced production equipment and testing equipment. With the strong technical, human and material resources, perfect management system.
  • RG59+2C PVC
    RG59+2C PVC

    CPR CLASS Eca

     

    1.- CABLE CONSTRUCTION
    Inner conductor Bare Copper 0.58 +/-0.01
    Elongation at break min 20%
    Adherence to dielectric 22 -89 N
    Dielectric polyethylene  3.70 +/-0.05
    Dielectric constant of base PE 2,25  
    Dielectric strength 1of PE 18 kV/mm  
    PE Oxidative Induction Time min. 30 minutes / ASTM D 4565 Chapter 17
    PE Oxidative Induction Time min. 70% after 14 days / 90 ºC
    First screen Copper Clad Aluminium Wire Braid 4,05 +/- 0,15
    Braid construction 16 x 7x (0,12+0,003/-0,003)  min. 84%
    Elongation at break for every wire min 6%
    Tensile strength for every wire  190N/mm2
    Power cord Bare Copper 24*0.20±0.02mm+1.80mm PVC BLACK 0.75mm2
    Bare Copper 24*0.20±0.01mm+ 1.80mm PVC RED 0.75mm2
    Power cord Out Sheath PVC  - NO BAD ODORS 4.80±3.0mm
    Sheath color BLACK RAL 9005 Thickness min. 0,5mm
    Jacket thickness excentricity  max. 43 % 
    Sheath PVC  - NO BAD ODORS 6.15 +/-0.20
    Sheath color BLACK RAL 9005 Thickness  0,8±0.1 mm
    Jacket thickness excentricity  max. 43 % 
    Tensile strength  min .11MPa(TM2)
    Tensile strength after 168 H at 80 ºc +/-20% (TM2)
    Elongation at break  min. 150 %(TM2)
    Elongation at break after 168 H at 80 ºC +/-20%(TM2)
    Bending test at low temperature -15°C
    Spark test  min. 2,5 kVrms
    Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm

     

    2. Cable environmental characteristics
    Environmental Space Indoor | Outdoor  
    Working temperature                                -20 ºC +75 ºC  
    CPR Cable Classifications Euro Class Eca EN50575: 2014+ A1:2016
    Flame Test Listing                                                                      vertical flame IEC 60332-1-2
    UV Resistance per UL 1581, Paragraph 1200

    Percent Retention of Tensile Strength & 

    Elongation after 720 hours 

    exposure shall be ≥ 80.

    UL2556

     

    3.- ELECTRICAL CHARACTERISTICS
    3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC
    Inner conductor resistance  Ohmios /km max. 65
    Outer conductor resistance  Ohmios /km max. 42
    Max. Loop current  Ampers 8 a 20 ºC - 5 a 40 ºC
    Dielectric strength  2 kV D.C. or 1,5 kV A.C. for 1 min.
    Insulation resistance  Mohm x km > 5000 Mohm x km
    Mutual capacitance  67±2nF/km
    Voltage test of sheath  2,5 kV A.C. or 3,75 kV D.C. for 1 min.
    3.2 Electrical characteristics - High frecuency - @ 20 ºC
    Velocity of propagation  % 66
    Characteristic impedance Ohmios 75 +/- 3
    Nominal Delay nS/m max.  5,1
    MHz dB/100m  NOM
    50 8.5
    100 11.8
    200 16.5
    450 26
    800 35.8
    800 35.8
    1000 39.5
    Return Loss 5 MHz - 1000 MHz  min. 20dB