23VAtC

23VAtC

23VAtC Specificatrion

CPR CLASS Eca

 

1.- CABLE CONSTRUCTION
Inner conductor Bare Copper 0,80+/- 0,01
Elongation at break min 20%
Adherence to dielectric 22 -89 N
Dielectric Gas injected foamed polyethylene  3,50 +/- 0,1 
Shrinkage max 4 % after 4 hours at 115 ºC  
Dielectric constant of base PE 2,25  
Dielectric strength 1of PE 18 kV/mm  
PE Oxidative Induction Time min. 30 minutes / ASTM D 4565 Chapter 17
PE Oxidative Induction Time min. 70% after 14 days / 90 ºC
First screen Tape Aluminium/Polyester/Aluminium 3,73 +/- 0,13 
dielectric - Ovality max. 0,28
Tape thickness0.009AL/0.012Pet/0.009A  
Overlapping min 18%
Second screen CUSN braid 4,10 +/- 0,15
Braid construction 52  x (0,10+0,01/-0,01)  min. 40%
Elongation at break for every wire min 20%
Tensile strength for every wire  150N/mm2
Sheath PVC  - NO BAD ODORS 5,00 +/-0.15
Sheath color WHITE  Thickness  0,50+/-0.05 mm
Jacket thickness excentricity  max. 43 % 
Tensile strength  min .11MPa(TM2)
Tensile strength after 168 H at 80 ºc +/- 20%(TM2)
Elongation at break  min. 150 %(TM2)
Elongation at break after 168 H at 80 ºC +/- 20%(TM2)
Spark test  min. 2,5 kVrms
Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm

 

2. Cable environmental characteristics
Environmental Space Indoor | Outdoor  
Working temperature                                -20 ºC +75 ºC  
CPR Cable Classifications Euro Class Eca EN50575: 2014+ A1:2016
Flame Test Listing                                                                      vertical flame IEC 60332-1-2
UV Resistance per UL 1581, Paragraph 1200

Percent Retention of Tensile Strength & 

Elongation after 720 hours 

exposure shall be ≥ 80.

UL2556

 

3- ELECTRICAL CHARACTERISTICS
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC
Inner conductor resistance  Ohmios /km max. 37
Outer conductor resistance  Ohmios /km max. 35
Max. Loop current  Ampers 8 a 20 ºC - 6 a 40 ºC
Dielectric strength  2 kV D.C. or 1,5 kV A.C. for 1 min.
Insulation resistance  Mohm x km > 10000 Mohm x km
Mutual capacitance  53±2nF/km 
Voltage test of sheath  2,5 kV A.C. or 3,75 kV D.C. for 1 min.
3.2 Electrical characteristics - High frecuency - @ 20 ºC
Velocity of propagation  % 84±2  
Characteristic impedance Ohmios 75 +/- 3   
Nominal Delay nS/m max.  4,0  
Transfer Impedance 5-30MHz ≤50mOhm/m IEC62153-4-3 
Shielding Effectiveness 30-1000MHz ≥75dB IEC62153-4-4 
1000-2000MHz ≥65dB
2000-3000MHz ≥55dB
Longitudinal attenuation MHz dB/100m  MAX  
10 3.0   
50 6.1   
100 8.0   
230 12.3   
300 14.2   
400 16.5   
470 18.5   
800 23.0   
860 25.5   
1000 26.8   
1350 31.5   
1750 36.4   
2150 40.3   
3000 48.0   
Return Loss  5 MHz - 470MHz  ≥20dB  
 470 MHz - 1000MHz  ≥18dB  
 1000 MHz - 2000MHz  ≥16dB  
 2000 MHz - 3000MHz  ≥15dB  
CONTACT WITH US