21VAtC

21VAtC

21VAtC Specificatrion

CPR CLASS Dca a2, s2 , d1

 

1.- CABLE CONSTRUCTION
Inner conductor Copper covered steel wire min. 21% 1,02+/- 0,01
Elongation at break min 1%
Tensile strength min. 380 N/mm2
Adherence to dielectric min. 22 N
Dielectric Gas injected foamed polyethylene  4,60 +/- 0,1 
Shrinkage max 4 % after 4 hours at 115 ºC  
Dielectric constant of base PE 2,25  
Dielectric strength 1of PE 18 kV/mm  
PE Oxidative Induction Time min. 30 minutes / ASTM D 4565 Chapter 17
PE Oxidative Induction Time min. 70% after 14 days / 90 ºC
First screen Tape Aluminium/Polyester/Aluminium 4,78 +/- 0,13 
dielectric - Ovality max. 0,33
Tape thickness0.009AL/0.012Pet/0.009AL  
Overlapping min 18%
Second screen Aluminum alloy braid 5,48 +/- 0,15
Type 5154A or (5056, 5154, 5954)  
Braid construction 16 x 8 x (0,12+0,01/-0,01)  min. 77%
Elongation at break for every wire min 3%
Tensile strength for every wire  300N/mm2
Third screen Tape Aluminium/Polyester/Aluminium 5,49+/- 0.15
0.009 AL/0.019Pet/0.009AL  
Overlapping  min 18%
Sheath LSZH  - NO BAD ODORS 7.10 +/-0.20
Sheath color WHITE RAL 9010 Thickness  0,80±0.1 mm
Jacket thickness excentricity  max. 43 % 
Tensile strength  min .12MPa  
Tensile strength after 168 H at 80 ºc +/-20%          
Elongation at break  min. 200%    
Elongation at break after 168 H at 80 ºC +/-20%          
Bending test at low temperature -40°C
Spark test  min. 2,5 kVrms
Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm

 

2. Cable environmental characteristics
Environmental Space Indoor | Outdoor  
Working temperature                                -20 ºC +75 ºC  
CPR Cable Classifications Euro Class Dca EN50575: 2014+ A1:2016
Flame Test Listing                                                                      vertical flame IEC 60332-1-2 EN 50399
Additional Classifications a2, s2 , d1
UV Resistance per UL 1581, Paragraph 1200

Percent Retention of Tensile Strength & 

Elongation after 720 hours 

exposure shall be ≥ 80.

UL2556

 

3- ELECTRICAL CHARACTERISTICS
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC
Inner conductor resistance  Ohmios /km max. 102
Outer conductor resistance  Ohmios /km max. 20
Max. Loop current  Ampers 8 a 20 ºC - 6 a 40 ºC
Dielectric strength  2 kV D.C. or 1,5 kV A.C. for 1 min.
Insulation resistance  Mohm x km > 10000 Mohm x km
Mutual capacitance  53±2nF/km 
Voltage test of sheath  2,5 kV A.C. or 3,75 kV D.C. for 1 min.
3.2 Electrical characteristics - High frecuency - @ 20 ºC
Velocity of propagation  % 84±2  
Characteristic impedance Ohmios 75 +/- 3   
Nominal Delay nS/m max.  4,0  
Transfer Impedance 5-30MHz ≤5mOhm/m IEC62153-4-3 
Shielding Effectiveness 30-1000MHz ≥95dB IEC62153-4-4 
1000-2000MHz ≥85dB
2000-3000MHz ≥75dB
Longitudinal attenuation MHz dB/100m  MAX  
10 2.46   
50 4.86   
100 6.56   
230 10.73   
300 11.65   
400 13.62   
470 14.78   
800 21.00   
860 20.05   
1000 21.49   
1350 24.71   
1750 28.67   
2150 31.79   
3000 37.53   
Return Loss 5 MHz - 470MHz  ≥20dB  
470 MHz - 1000MHz  ≥18dB  
1000 MHz - 2000MHz  ≥16dB  
2000 MHz - 3000MHz  ≥15dB  
CONTACT WITH US