17VAtC CPR

17VAtC CPR

17VAtC CPR Specificatrion

17VAtC CPR CLASS Dca a2, s2 , d1

 

1.- 17VATC WITH CPR CABLE CONSTRUCTION
Inner conductor Copper covered steel wire min. 21% 1,13+/- 0,03
Elongation at break min 1%
Tensile strength min. 380 N/mm2
Adherence to dielectric min. 22 N
Dielectric Gas injected foamed polyethylene  4,80 +/- 0,1 
Shrinkage max 4 % after 4 hours at 115 ºC  
Dielectric constant of base PE 2,25  
Dielectric strength 1of PE 18 kV/mm  
PE Oxidative Induction Time min. 30 minutes / ASTM D 4565 Chapter 17
PE Oxidative Induction Time min. 70% after 14 days / 90 ºC
First screen Tape Aluminium/Polyester/Aluminium 4,88 +/- 0,13 
dielectric - Ovality max. 0,33
Tape thickness 0.009AL/0.012Pet/0.009AL  
Overlapping min 18%
Second screen Aluminum alloy braid 5,48 +/- 0,15
Type 5154A or (5056, 5154, 5954)  
Braid construction 16 x 8 x (0,12+0,01/-0,01)  min. 77%
Elongation at break for every wire min 3%
Tensile strength for every wire  300N/mm2
Third screen Tape Aluminium/Polyester/Aluminium 5,49+/- 0.15
0.009 AL/0.019Pet/0.009AL  
Overlapping  min 18%
Sheath LSZH  - NO BAD ODORS 7.10 +/-0.20
Sheath color WHITE RAL 9010 Thickness  0,80±0.1 mm
Jacket thickness excentricity  max. 43 % 
Tensile strength  min .12MPa  
Tensile strength after 168 H at 80 ºc +/-20%          
Elongation at break  min. 200%    
Elongation at break after 168 H at 80 ºC +/-20%          
Bending test at low temperature -40°C
Spark test  min. 2,5 kVrms
Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm

 

2. 17VATC WITH CPR Cable environmental characteristics
Environmental Space Indoor | Outdoor  
Working temperature                                -20 ºC +75 ºC  
CPR Cable Classifications Euro Class Dca EN50575: 2014+ A1:2016
Flame Test Listing                                                                      vertical flame IEC 60332-1-2EN 50399
Additional Classifications a2, s2 , d1
UV Resistance per UL 1581, Paragraph 1200

Percent Retention of Tensile Strength & 

Elongation after 720 hours

exposure shall be ≥ 80.

UL2556

 

3- 17VATC WITH CPR ELECTRICAL CHARACTERISTICS
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC
Inner conductor resistance    Ohmios /km max. 81  
Outer conductor resistance    Ohmios /km max. 20  
Max. Loop current    Ampers 8 a 20 ºC - 6 a 40 ºC  
Dielectric strength    2 kV D.C. or 1,5 kV A.C. for 1 min.  
Insulation resistance    Mohm x km > 10000 Mohm x km  
Mutual capacitance    53±2nF/km   
Voltage test of sheath    2,5 kV A.C. or 3,75 kV D.C. for 1 min.  
3.2 Electrical characteristics - High frecuency - @ 20 ºC
Velocity of propagation  % 84±2  
Characteristic impedance Ohmios 75 +/- 3   
Nominal Delay nS/m max.  4,0  
Transfer Impedance 5-30MHz ≤5mOhm/m IEC62153-4-3 
Shielding Effectiveness 30-1000MHz ≥95dB IEC62153-4-4 
1000-2000MHz ≥85dB
2000-3000MHz ≥75dB
Longitudinal attenuation MHz dB/100m  MAX  
50 4.30   
100 5.20   
200 8.40   
470 13.40   
800 17.00   
1000 19.50   
1350 23.00   
1750 26.20   
2150 29.50   
2400 31.90   
2700 33.60   
3000 36.59   
Return Loss 5 MHz - 470MHz  ≥20dB  
470 MHz - 1000MHz  ≥18dB  
1000 MHz - 2000MHz  ≥16dB  
2000 MHz - 3000MHz  ≥15dB  

 