11VATC CPR

11VATC CPR

11VATC CPR Specificatrion

11VATC WITH CPR CLASS Dca a2, s2 , d1

 

1.-11VATC WITH CPR CABLE CONSTRUCTION
Inner conductor Copper covered steel wire min. 21% 1,63+/- 0,03
Elongation at break min 1%
Tensile strength min. 380 N/mm2
Adherence to dielectric min. 22 N
Dielectric Gas injected foamed polyethylene  7,20 +/- 0,1 
Shrinkage max 4 % after 4 hours at 115 ºC  
Dielectric constant of base PE 2,25  
Dielectric strength 1of PE 18 kV/mm  
PE Oxidative Induction Time min. 30 minutes / ASTM D 4565 Chapter 17
PE Oxidative Induction Time min. 70% after 14 days / 90 ºC
First screen Tape Aluminium/Polyester/Aluminium 7,32 +/- 0,15
dielectric - Ovality max. 0,38
0.009AL/0.012Pet/0.009AL  
Overlapping min 18%
Second screen Aluminum alloy braid 7.99 +/- 0,15
Type 5154A or (5056, 5154, 5954)  
Braid construction 24 x 6 x (0,16+0,01/-0,01)  min. 90%
Elongation at break for every wire min 3%
Tensile strength for every wire  300N/mm2
Third screen Tape Aluminium/Polyester/Aluminium 8.20+/- 0.25
0.009 AL/0.019Pet/0.009AL  
Overlapping  min 18%
Sheath LSZH  - NO BAD ODORS 10.16 +/-0.25
Sheath color BLACK RAL 9005 Thickness  1,00±0.1 mm
Jacket thickness excentricity  max. 43 % 
Tensile strength  min .12MPa  
Tensile strength after 168 H at 80 ºc +/-20%          
Elongation at break  min. 200%    
Elongation at break after 168 H at 80 ºC +/-20%          
Bending test at low temperature -40°C
Spark test  min. 2,5 kVrms
Jacket shrinkage (ANSI/SCTE 88/2003) max. 10 mm / sample 150 mm

 

2.11VATC WITH CPR Cable environmental characteristics
Environmental Space Indoor | Outdoor  
Working temperature                                -20 ºC +75 ºC  
CPR Cable Classifications Euro Class Dca EN50575: 2014+ A1:2016
Flame Test Listing                                                                      vertical flame

IEC 6033212 

EN 50399

Additional Classifications a2, s2 , d1
UV Resistance per UL 1581, Paragraph 1200

Percent Retention of Tensile 

Strength & Elongation after 

720 hours exposure shall be ≥ 80.

UL2556

 

3- 11VATC WITH CPR ELECTRICAL CHARACTERISTICS
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC
Inner conductor resistance  Ohmios /km max. 39
Outer conductor resistance  Ohmios /km max. 15
Max. Loop current  Ampers 8 a 20 ºC - 6 a 40 ºC
Dielectric strength  2 kV D.C. or 1,5 kV A.C. for 1 min.
Insulation resistance  Mohm x km > 10000 Mohm x km
Mutual capacitance  53±2nF/km 
Voltage test of sheath  2,5 kV A.C. or 3,75 kV D.C. for 1 min.
3.2 Electrical characteristics - High frecuency - @ 20 ºC
Velocity of propagation  % 84±2  
Characteristic impedance Ohmios 75 +/- 3   
Nominal Delay nS/m max.  4,0  
Transfer Impedance 5-30MHz ≤5mOhm/m IEC62153-4-3 
Shielding Effectiveness 30-1000MHz ≥95dB IEC62153-4-4 
1000-2000MHz ≥85dB
2000-3000MHz ≥75dB
Longitudinal attenuation MHz dB/100m  MAX  
5 1.25   
50 3.14   
200 6.05   
470 9.56   
800 11.00   
1000 14.27   
1350 18.10   
1750 20.90   
2150 22.53   
2400 23.95   
2700 24.46   
3000 26.64   
Return Loss  5 MHz - 470MHz  ≥20dB  
 470 MHz - 1000MHz  ≥18dB  
 1000 MHz - 2000MHz  ≥16dB  
 2000 MHz - 3000MHz  ≥15dB  