1.CABLE CONSTRUCTION | ||
Inner conductor | Bare Copper | 0,58+/- 0,01 |
Elongation at break | min 20% | |
Adherence to dielectric | 22 -89 N | |
Dielectric | polyethylene | 3.70 +/-0.05 |
Dielectric constant of base PE 2,25 | ||
Dielectric strength 1of PE 18 kV/mm | ||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | |
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | |
First screen | Copper Clad Aluminium Wire Braid | 4,05 +/- 0,15 |
Braid construction 16 x 9x (0,12+0,003/-0,003) | min. 95% | |
Elongation at break for every wire | min 6% | |
Tensile strength for every wire | 190N/mm2 | |
Sheath | LSZH - NO BAD ODORS | 6.15 +/-0.20 |
Sheath color BLACK RAL 9005 | Thickness 0,8±0.1 mm | |
Jacket thickness excentricity | max. 43 % | |
Tensile strength | min .12MPa | |
Tensile strength after 168 H at 80 ºc | +/-20% | |
Elongation at break | min. 200% | |
Elongation at break after 168 H at 80 ºC | +/-20% | |
Bending test at low temperature | -40°C | |
Spark test | min. 2,5 kVrms | |
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm | |
Sheath marking | ||
Delivery form |
2. Cable environmental characteristics | ||
Environmental Space | Indoor | Outdoor | |
Working temperature | -20 ºC +75 ºC | |
CPR Cable Classifications | Euro Class Dca | EN50575: 2014+ A1:2016 |
Flame Test Listing | vertical flame |
IEC 60332-1-2 EN 50399 |
Additional Classifications | a2, s2 , d1 | |
UV Resistance per UL 1581, Paragraph 1200 | Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. | UL2556 |
3.ELECTRICAL CHARACTERISTICS | ||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | ||
Inner conductor resistance | Ohmios /km max. 65 | |
Outer conductor resistance | Ohmios /km max. 18 | |
Max. Loop current | Ampers 8 a 20 ºC - 5 a 40 ºC | |
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | |
Insulation resistance | Mohm x km > 5000 Mohm x km | |
Mutual capacitance | 67±2nF/km | |
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | |
3.2 Electrical characteristics - High frecuency - @ 20 ºC | ||
Velocity of propagation | % | 66 |
Characteristic impedance | Ohmios | 75 +/- 3 |
Nominal Delay | nS/m max. | 5,1 |
MHz | dB/100m NOM | |
50 | 8.5 | |
100 | 11.8 | |
200 | 16.5 | |
450 | 26 | |
800 | 35.8 | |
800 | 35.8 | |
1000 | 39.5 | |
Return Loss | 5 MHz - 1000 MHz | min. 20dB |
1.-11VATC WITH CPR CABLE CONSTRUCTION | |||
Inner conductor | Copper covered steel wire min. 21% | 1,63+/- 0,03 | |
Elongation at break | min 1% | ||
Tensile strength | min. 380 N/mm2 | ||
Adherence to dielectric | min. 22 N | ||
Dielectric | Gas injected foamed polyethylene | 7,20 +/- 0,1 | |
Shrinkage max 4 % after 4 hours at 115 ºC | |||
Dielectric constant of base PE 2,25 | |||
Dielectric strength 1of PE 18 kV/mm | |||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | ||
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | ||
First screen | Tape Aluminium/Polyester/Aluminium | 7,32 +/- 0,15 | |
dielectric - Ovality | max. 0,38 | ||
0.009AL/0.012Pet/0.009AL | |||
Overlapping | min 18% | ||
Second screen | Aluminum alloy braid | 7.99 +/- 0,15 | |
Type 5154A or (5056, 5154, 5954) | |||
Braid construction 24 x 6 x (0,16+0,01/-0,01) | min. 90% | ||
Elongation at break for every wire | min 3% | ||
Tensile strength for every wire | 300N/mm2 | ||
Third screen | Tape Aluminium/Polyester/Aluminium | 8.20+/- 0.25 | |
0.009 AL/0.019Pet/0.009AL | |||
Overlapping | min 18% | ||
Sheath | LSZH - NO BAD ODORS | 10.16 +/-0.25 | |
Sheath color BLACK RAL 9005 | Thickness 1,00±0.1 mm | ||
Jacket thickness excentricity | max. 43 % | ||
Tensile strength | min .12MPa | ||
Tensile strength after 168 H at 80 ºc | +/-20% | ||
Elongation at break | min. 200% | ||
Elongation at break after 168 H at 80 ºC | +/-20% | ||
Bending test at low temperature | -40°C | ||
Spark test | min. 2,5 kVrms | ||
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2.11VATC WITH CPR Cable environmental characteristics | ||||
Environmental Space | Indoor | Outdoor | |||
Working temperature | -20 ºC +75 ºC | |||
CPR Cable Classifications | Euro Class Dca | EN50575: 2014+ A1:2016 | ||
Flame Test Listing | vertical flame |
IEC 6033212 EN 50399 |
||
Additional Classifications | a2, s2 , d1 | |||
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3- 11VATC WITH CPR ELECTRICAL CHARACTERISTICS | ||||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | ||||
Inner conductor resistance | Ohmios /km max. 39 | |||
Outer conductor resistance | Ohmios /km max. 15 | |||
Max. Loop current | Ampers 8 a 20 ºC - 6 a 40 ºC | |||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | |||
Insulation resistance | Mohm x km > 10000 Mohm x km | |||
Mutual capacitance | 53±2nF/km | |||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | |||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | ||||
Velocity of propagation | % | 84±2 | ||
Characteristic impedance | Ohmios | 75 +/- 3 | ||
Nominal Delay | nS/m max. | 4,0 | ||
Transfer Impedance | 5-30MHz | ≤5mOhm/m | IEC62153-4-3 | |
Shielding Effectiveness | 30-1000MHz | ≥95dB | IEC62153-4-4 | |
1000-2000MHz | ≥85dB | |||
2000-3000MHz | ≥75dB | |||
Longitudinal attenuation | MHz | dB/100m MAX | ||
5 | 1.25 | |||
50 | 3.14 | |||
200 | 6.05 | |||
470 | 9.56 | |||
800 | 11.00 | |||
1000 | 14.27 | |||
1350 | 18.10 | |||
1750 | 20.90 | |||
2150 | 22.53 | |||
2400 | 23.95 | |||
2700 | 24.46 | |||
3000 | 26.64 | |||
Return Loss | 5 MHz - 470MHz | ≥20dB | ||
470 MHz - 1000MHz | ≥18dB | |||
1000 MHz - 2000MHz | ≥16dB | |||
2000 MHz - 3000MHz | ≥15dB |
1.- 17VATC WITH CPR CABLE CONSTRUCTION | ||
Inner conductor | Copper covered steel wire min. 21% | 1,13+/- 0,03 |
Elongation at break | min 1% | |
Tensile strength | min. 380 N/mm2 | |
Adherence to dielectric | min. 22 N | |
Dielectric | Gas injected foamed polyethylene | 4,80 +/- 0,1 |
Shrinkage max 4 % after 4 hours at 115 ºC | ||
Dielectric constant of base PE 2,25 | ||
Dielectric strength 1of PE 18 kV/mm | ||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | |
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | |
First screen | Tape Aluminium/Polyester/Aluminium | 4,88 +/- 0,13 |
dielectric - Ovality | max. 0,33 | |
Tape thickness 0.009AL/0.012Pet/0.009AL | ||
Overlapping | min 18% | |
Second screen | Aluminum alloy braid | 5,48 +/- 0,15 |
Type 5154A or (5056, 5154, 5954) | ||
Braid construction 16 x 8 x (0,12+0,01/-0,01) | min. 77% | |
Elongation at break for every wire | min 3% | |
Tensile strength for every wire | 300N/mm2 | |
Third screen | Tape Aluminium/Polyester/Aluminium | 5,49+/- 0.15 |
0.009 AL/0.019Pet/0.009AL | ||
Overlapping | min 18% | |
Sheath | LSZH - NO BAD ODORS | 7.10 +/-0.20 |
Sheath color WHITE RAL 9010 | Thickness 0,80±0.1 mm | |
Jacket thickness excentricity | max. 43 % | |
Tensile strength | min .12MPa | |
Tensile strength after 168 H at 80 ºc | +/-20% | |
Elongation at break | min. 200% | |
Elongation at break after 168 H at 80 ºC | +/-20% | |
Bending test at low temperature | -40°C | |
Spark test | min. 2,5 kVrms | |
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2. 17VATC WITH CPR Cable environmental characteristics | ||||
Environmental Space | Indoor | Outdoor | |||
Working temperature | -20 ºC +75 ºC | |||
CPR Cable Classifications | Euro Class Dca | EN50575: 2014+ A1:2016 | ||
Flame Test Listing | vertical flame | IEC 60332-1-2EN 50399 | ||
Additional Classifications | a2, s2 , d1 | |||
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3- 17VATC WITH CPR ELECTRICAL CHARACTERISTICS | |||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | |||
Inner conductor resistance | Ohmios /km max. 81 | ||
Outer conductor resistance | Ohmios /km max. 20 | ||
Max. Loop current | Ampers 8 a 20 ºC - 6 a 40 ºC | ||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | ||
Insulation resistance | Mohm x km > 10000 Mohm x km | ||
Mutual capacitance | 53±2nF/km | ||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | ||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | |||
Velocity of propagation | % | 84±2 | |
Characteristic impedance | Ohmios | 75 +/- 3 | |
Nominal Delay | nS/m max. | 4,0 | |
Transfer Impedance | 5-30MHz | ≤5mOhm/m | IEC62153-4-3 |
Shielding Effectiveness | 30-1000MHz | ≥95dB | IEC62153-4-4 |
1000-2000MHz | ≥85dB | ||
2000-3000MHz | ≥75dB | ||
Longitudinal attenuation | MHz | dB/100m MAX | |
50 | 4.30 | ||
100 | 5.20 | ||
200 | 8.40 | ||
470 | 13.40 | ||
800 | 17.00 | ||
1000 | 19.50 | ||
1350 | 23.00 | ||
1750 | 26.20 | ||
2150 | 29.50 | ||
2400 | 31.90 | ||
2700 | 33.60 | ||
3000 | 36.59 | ||
Return Loss | 5 MHz - 470MHz | ≥20dB | |
470 MHz - 1000MHz | ≥18dB | ||
1000 MHz - 2000MHz | ≥16dB | ||
2000 MHz - 3000MHz | ≥15dB |
1.- CABLE CONSTRUCTION | ||
Inner conductor | Copper covered steel wire min. 21% | 1,02+/- 0,01 |
Elongation at break | min 1% | |
Tensile strength | min. 380 N/mm2 | |
Adherence to dielectric | min. 22 N | |
Dielectric | Gas injected foamed polyethylene | 4,80 +/- 0,1 |
Shrinkage max 4 % after 4 hours at 115 ºC | ||
Dielectric constant of base PE 2,25 | ||
Dielectric strength 1of PE 18 kV/mm | ||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | |
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | |
First screen | Tape Aluminium/Polyester/Aluminium | 4,88 +/- 0,13 |
dielectric - Ovality | max. 0,33 | |
Tape thickness0.009AL/0.012Pet/0.009AL | ||
Overlapping | min 18% | |
Second screen | Aluminum alloy braid | 5,48 +/- 0,15 |
Type 5154A or (5056, 5154, 5954) | ||
Braid construction 16 x 8 x (0,12+0,01/-0,01) | min. 77% | |
Elongation at break for every wire | min 3% | |
Tensile strength for every wire | 300N/mm2 | |
Third screen | Tape Aluminium/Polyester/Aluminium | 5,49+/- 0.15 |
0.009 AL/0.019Pet/0.009AL | ||
Overlapping | min 18% | |
Sheath | LSZH - NO BAD ODORS | 7.10 +/-0.20 |
Sheath color WHITE RAL 9010 | Thickness 0,80±0.1 mm | |
Jacket thickness excentricity | max. 43 % | |
Tensile strength | min .12MPa | |
Tensile strength after 168 H at 80 ºc | +/-20% | |
Elongation at break | min. 200% | |
Elongation at break after 168 H at 80 ºC | +/-20% | |
Bending test at low temperature | -40°C | |
Spark test | min. 2,5 kVrms | |
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2. Cable environmental characteristics | ||||
Environmental Space | Indoor | Outdoor | |||
Working temperature | -20 ºC +75 ºC | |||
CPR Cable Classifications | Euro Class Dca | EN50575: 2014+ A1:2016 | ||
Flame Test Listing | vertical flame | IEC 60332-1-2 EN 50399 | ||
Additional Classifications | a2, s2 , d1 | |||
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3- ELECTRICAL CHARACTERISTICS | ||||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | ||||
Inner conductor resistance | Ohmios /km max. 102 | |||
Outer conductor resistance | Ohmios /km max. 20 | |||
Max. Loop current | Ampers 8 a 20 ºC - 6 a 40 ºC | |||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | |||
Insulation resistance | Mohm x km > 10000 Mohm x km | |||
Mutual capacitance | 53±2nF/km | |||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | |||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | ||||
Velocity of propagation | % | 84±2 | ||
Characteristic impedance | Ohmios | 75 +/- 3 | ||
Nominal Delay | nS/m max. | 4,0 | ||
Transfer Impedance | 5-30MHz | ≤5mOhm/m | IEC62153-4-3 | |
Shielding Effectiveness | 30-1000MHz | ≥95dB | IEC62153-4-4 | |
1000-2000MHz | ≥85dB | |||
2000-3000MHz | ≥75dB | |||
Longitudinal attenuation | MHz | dB/100m MAX | ||
50 | 4.60 | |||
100 | 6.50 | |||
200 | 9.00 | |||
470 | 14.50 | |||
800 | 18.00 | |||
1000 | 21.10 | |||
1350 | 25.00 | |||
1750 | 27.90 | |||
2150 | 32.00 | |||
2400 | 33.20 | |||
2700 | 36.70 | |||
3000 | 39.30 | |||
Return Loss | 5 MHz - 470MHz | ≥20dB | ||
470 MHz - 1000MHz | ≥18dB | |||
1000 MHz - 2000MHz | ≥16dB | |||
2000 MHz - 3000MHz | ≥15dB |
1.- CABLE CONSTRUCTION | ||
Inner conductor | Copper covered steel wire min. 21% | 1,00+/- 0,01 |
Elongation at break | min 1% | |
Tensile strength | min. 380 N/mm2 | |
Adherence to dielectric | min. 22 N | |
Dielectric | Gas injected foamed polyethylene | 4,70 +/- 0,1 |
Shrinkage max 4 % after 4 hours at 115 ºC | ||
Dielectric constant of base PE 2,25 | ||
Dielectric strength 1of PE 18 kV/mm | ||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | |
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | |
First screen | Tape Aluminium/Polyester/Aluminium | 4,88 +/- 0,13 |
dielectric - Ovality | max. 0,33 | |
Tape thickness0.009AL/0.012Pet/0.009AL | ||
Overlapping | min 18% | |
Second screen | Aluminum alloy braid | 5,48 +/- 0,15 |
Type 5154A or (5056, 5154, 5954) | ||
Braid construction 16 x 8 x (0,12+0,01/-0,01) | min. 77% | |
Elongation at break for every wire | min 3% | |
Third screen | Tape Aluminium/Polyester/Aluminium | 5,49+/- 0.15 |
0.009 AL/0.019Pet/0.009AL | ||
Overlapping | min 18% | |
Sheath | LSZH - NO BAD ODORS | 7.10 +/-0.20 |
Sheath color WHITE RAL 9010 | Thickness 0,80±0.1 mm | |
Jacket thickness excentricity | max. 43 % | |
Tensile strength | min .12MPa | |
Tensile strength after 168 H at 80 ºc | +/-20% | |
Elongation at break | min. 200% | |
Elongation at break after 168 H at 80 ºC | +/-20% | |
Bending test at low temperature | -40°C | |
Spark test | min. 2,5 kVrms | |
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2. Cable environmental characteristics | ||||
Environmental Space | Indoor | Outdoor | |||
Working temperature | -20 ºC +75 ºC | |||
CPR Cable Classifications | Euro Class Dca | EN50575: 2014+ A1:2016 | ||
Flame Test Listing | vertical flame | IEC 60332-1-2 EN 50399 | ||
Additional Classifications | a2, s2 , d1 | |||
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3- ELECTRICAL CHARACTERISTICS | ||||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | ||||
Inner conductor resistance | Ohmios /km max. 104 | |||
Outer conductor resistance | Ohmios /km max. 20 | |||
Max. Loop current | Ampers 8 a 20 ºC - 6 a 40 ºC | |||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | |||
Insulation resistance | Mohm x km > 10000 Mohm x km | |||
Mutual capacitance | 53±2nF/km | |||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | |||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | ||||
Velocity of propagation | % | 84±2 | ||
Characteristic impedance | Ohmios | 75 +/- 3 | ||
Nominal Delay | nS/m max. | 4,0 | ||
Transfer Impedance | 5-30MHz | ≤5mOhm/m | IEC62153-4-3 | |
Shielding Effectiveness | 30-1000MHz | ≥95dB | IEC62153-4-4 | |
1000-2000MHz | ≥85dB | |||
2000-3000MHz | ≥75dB | |||
Longitudinal attenuation | MHz | dB/100m MAX | ||
50 | 4.60 | |||
100 | 6.50 | |||
200 | 9.00 | |||
470 | 14.50 | |||
800 | 19.00 | |||
1000 | 21.10 | |||
1350 | 25.00 | |||
1750 | 27.90 | |||
2150 | 32.40 | |||
2400 | 34.10 | |||
2700 | 36.70 | |||
3000 | 39.30 | |||
Return Loss | 5 MHz - 470MHz | ≥20dB | ||
470 MHz - 1000MHz | ≥18dB | |||
1000 MHz - 2000MHz | ≥16dB | |||
2000 MHz - 3000MHz | ≥15dB |
1.- CABLE CONSTRUCTION | ||
Inner conductor | Copper covered steel wire min. 21% | 1,02+/- 0,01 |
Elongation at break | min 1% | |
Tensile strength | min. 380 N/mm2 | |
Adherence to dielectric | min. 22 N | |
Dielectric | Gas injected foamed polyethylene | 4,60 +/- 0,1 |
Shrinkage max 4 % after 4 hours at 115 ºC | ||
Dielectric constant of base PE 2,25 | ||
Dielectric strength 1of PE 18 kV/mm | ||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | |
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | |
First screen | Tape Aluminium/Polyester/Aluminium | 4,78 +/- 0,13 |
dielectric - Ovality | max. 0,33 | |
Tape thickness0.009AL/0.012Pet/0.009AL | ||
Overlapping | min 18% | |
Second screen | Aluminum alloy braid | 5,48 +/- 0,15 |
Type 5154A or (5056, 5154, 5954) | ||
Braid construction 16 x 8 x (0,12+0,01/-0,01) | min. 77% | |
Elongation at break for every wire | min 3% | |
Tensile strength for every wire | 300N/mm2 | |
Third screen | Tape Aluminium/Polyester/Aluminium | 5,49+/- 0.15 |
0.009 AL/0.019Pet/0.009AL | ||
Overlapping | min 18% | |
Sheath | LSZH - NO BAD ODORS | 7.10 +/-0.20 |
Sheath color WHITE RAL 9010 | Thickness 0,80±0.1 mm | |
Jacket thickness excentricity | max. 43 % | |
Tensile strength | min .12MPa | |
Tensile strength after 168 H at 80 ºc | +/-20% | |
Elongation at break | min. 200% | |
Elongation at break after 168 H at 80 ºC | +/-20% | |
Bending test at low temperature | -40°C | |
Spark test | min. 2,5 kVrms | |
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2. Cable environmental characteristics | ||||
Environmental Space | Indoor | Outdoor | |||
Working temperature | -20 ºC +75 ºC | |||
CPR Cable Classifications | Euro Class Dca | EN50575: 2014+ A1:2016 | ||
Flame Test Listing | vertical flame | IEC 60332-1-2 EN 50399 | ||
Additional Classifications | a2, s2 , d1 | |||
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3- ELECTRICAL CHARACTERISTICS | ||||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | ||||
Inner conductor resistance | Ohmios /km max. 102 | |||
Outer conductor resistance | Ohmios /km max. 20 | |||
Max. Loop current | Ampers 8 a 20 ºC - 6 a 40 ºC | |||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | |||
Insulation resistance | Mohm x km > 10000 Mohm x km | |||
Mutual capacitance | 53±2nF/km | |||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | |||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | ||||
Velocity of propagation | % | 84±2 | ||
Characteristic impedance | Ohmios | 75 +/- 3 | ||
Nominal Delay | nS/m max. | 4,0 | ||
Transfer Impedance | 5-30MHz | ≤5mOhm/m | IEC62153-4-3 | |
Shielding Effectiveness | 30-1000MHz | ≥95dB | IEC62153-4-4 | |
1000-2000MHz | ≥85dB | |||
2000-3000MHz | ≥75dB | |||
Longitudinal attenuation | MHz | dB/100m MAX | ||
10 | 2.46 | |||
50 | 4.86 | |||
100 | 6.56 | |||
230 | 10.73 | |||
300 | 11.65 | |||
400 | 13.62 | |||
470 | 14.78 | |||
800 | 21.00 | |||
860 | 20.05 | |||
1000 | 21.49 | |||
1350 | 24.71 | |||
1750 | 28.67 | |||
2150 | 31.79 | |||
3000 | 37.53 | |||
Return Loss | 5 MHz - 470MHz | ≥20dB | ||
470 MHz - 1000MHz | ≥18dB | |||
1000 MHz - 2000MHz | ≥16dB | |||
2000 MHz - 3000MHz | ≥15dB |
1.- CABLE CONSTRUCTION | |||
Inner conductor | Bare Copper | 0,80+/- 0,01 | |
Elongation at break | min 20% | ||
Adherence to dielectric | 22 -89 N | ||
Dielectric | Gas injected foamed polyethylene | 3,50 +/- 0,1 | |
Shrinkage max 4 % after 4 hours at 115 ºC | |||
Dielectric constant of base PE 2,25 | |||
Dielectric strength 1of PE 18 kV/mm | |||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | ||
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | ||
First screen | Tape Aluminium/Polyester/Aluminium | 3,73 +/- 0,13 | |
dielectric - Ovality | max. 0,28 | ||
Tape thickness0.009AL/0.012Pet/0.009A | |||
Overlapping | min 18% | ||
Second screen | CUSN braid | 4,10 +/- 0,15 | |
Braid construction 52 x (0,10+0,01/-0,01) | min. 40% | ||
Elongation at break for every wire | min 20% | ||
Tensile strength for every wire | 150N/mm2 | ||
Third screen | Tape Aluminium/Polyester/Aluminium | 4,49+/- 0.15 | |
0.009 AL/0.019Pet/0.009AL | |||
Overlapping | min 18% | ||
Sheath | LSZH - NO BAD ODORS | 5.20 +/-0.20 | |
Sheath color WHITE RAL 9010 | Thickness 0,55±0.1 mm | ||
Jacket thickness excentricity | max. 43 % | ||
Tensile strength | min .12MPa | ||
Tensile strength after 168 H at 80 ºc | +/-20% | ||
Elongation at break | min. 200% | ||
Elongation at break after 168 H at 80 ºC | +/-20% | ||
Bending test at low temperature | -40°C | ||
Spark test | min. 2,5 kVrms | ||
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2. Cable environmental characteristics | ||||
Environmental Space | Indoor | Outdoor | |||
Working temperature | -20 ºC +75 ºC | |||
CPR Cable Classifications | Euro Class Dca | EN50575: 2014+ A1:2016 | ||
Flame Test Listing | vertical flame | IEC 60332-12 EN 50399 | ||
Additional Classifications | a2, s2 , d1 | |||
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3- ELECTRICAL CHARACTERISTICS | |||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | |||
Inner conductor resistance | Ohmios /km max. 37 | ||
Outer conductor resistance | Ohmios /km max. 24 | ||
Max. Loop current | Ampers 8 a 20 ºC - 6 a 40 ºC | ||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | ||
Insulation resistance | Mohm x km > 10000 Mohm x km | ||
Mutual capacitance | 53±2nF/km | ||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | ||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | |||
Velocity of propagation | % | 84±2 | |
Characteristic impedance | Ohmios | 75 +/- 3 | |
Nominal Delay | nS/m max. | 4,0 | |
Transfer Impedance | 5-30MHz | ≤15mOhm/m | IEC62153-4-3 |
Shielding Effectiveness | 30-1000MHz | ≥85dB | IEC62153-4-4 |
1000-2000MHz | ≥75dB | ||
2000-3000MHz | ≥65dB | ||
Longitudinal attenuation | MHz | dB/100m MAX | |
10 | 3.0 | ||
50 | 6.1 | ||
100 | 8.0 | ||
230 | 12.3 | ||
300 | 14.2 | ||
400 | 16.5 | ||
470 | 18.5 | ||
800 | 23.0 | ||
860 | 25.5 | ||
1000 | 26.8 | ||
1350 | 31.5 | ||
1750 | 36.4 | ||
2150 | 40.3 | ||
3000 | 48.0 | ||
Return Loss | 5 MHz - 470MHz | ≥20dB | |
470 MHz - 1000MHz | ≥18dB | ||
1000 MHz - 2000MHz | ≥16dB | ||
2000 MHz - 3000MHz | ≥15dB |
1.- CABLE CONSTRUCTION | |||
Inner conductor | Copper covered steel wire min. 21% | 1,63+/- 0,03 | |
Elongation at break | min 1% | ||
Tensile strength | min. 380 N/mm2 | ||
Adherence to dielectric | min. 22 N | ||
Dielectric | Gas injected foamed polyethylene | 7,20 +/- 0,1 | |
Shrinkage max 4 % after 4 hours at 115 ºC | |||
Dielectric constant of base PE 2,25 | |||
Dielectric strength 1of PE 18 kV/mm | |||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | ||
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | ||
First screen | Tape Aluminium/Polyester/Aluminium | 7,32 +/- 0,15 | |
dielectric - Ovality | max. 0,38 | ||
Tape thickness | |||
Overlapping | min 18% | ||
Second screen | Aluminum alloy braid | 7.99 +/- 0,15 | |
Type 5154A or (5056, 5154, 5954) | |||
Braid construction 16 x 6 x (0,16+0,01/-0,01) | min. 60% | ||
Elongation at break for every wire | min 3% | ||
Tensile strength for every wire | 300N/mm2 | ||
Sheath | PVC - NO BAD ODORS | 10,16 +/-0.20 | |
Sheath color BLACK | Thickness 1,10+/-0.10 mm | ||
Jacket thickness excentricity | max. 43 % | ||
Tensile strength | min .13.8MPa(TM2) | ||
Tensile strength after 168 H at 80 ºc | +/- 20% (TM2) | ||
Elongation at break | min. 250 %(TM2) | ||
Elongation at break after 168 H at 80 ºC | +/- 20%(TM2) | ||
Spark test | min. 2,5 kVrms | ||
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2. Cable environmental characteristics | ||||
Working temperature | -20 ºC +75 ºC | |||
Environmental Space | Indoor | Outdoor | |||
CPR Cable Classifications | Euro Class Eca | EN50575: 2014+ A1:2016 | ||
Flame Test Listing | vertical flame | IEC 60332-1-2 | ||
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3- ELECTRICAL CHARACTERISTICS | ||||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | ||||
Inner conductor resistance | Ohmios /km max. 39 | |||
Outer conductor resistance | Ohmios /km max. 21 | |||
Max. Loop current | Ampers 8 a 20 ºC - 6 a 40 ºC | |||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | |||
Insulation resistance | Mohm x km > 10000 Mohm x km | |||
Mutual capacitance | 53±2nF/km | |||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | |||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | ||||
Velocity of propagation | % | 84±2 | ||
Characteristic impedance | Ohmios | 75 +/- 3 | ||
Nominal Delay | nS/m max. | 4,0 | ||
Transfer Impedance | 5-30MHz | ≤15mOhm/m | IEC62153-4-3 | |
Shielding Effectiveness | 30-1000MHz | ≥85dB | IEC62153-4-4 | |
1000-2000MHz | ≥75dB | |||
2000-3000MHz | ≥65dB | |||
Longitudinal attenuation | MHz | dB/100m MAX | ||
5 | 1.25 | |||
50 | 3.14 | |||
200 | 6.05 | |||
470 | 9.56 | |||
800 | 11.00 | |||
1000 | 14.27 | |||
1350 | 18.10 | |||
1750 | 20.90 | |||
2150 | 22.53 | |||
2400 | 23.95 | |||
2700 | 24.46 | |||
3000 | 26.64 | |||
Return Loss | 5 MHz - 470MHz | ≥20dB | ||
470 MHz - 1000MHz | ≥18dB | |||
1000 MHz - 2000MHz | ≥16dB | |||
2000 MHz - 3000MHz | ≥15dB |
1.- CABLE CONSTRUCTION | |||
Inner conductor | Copper covered steel wire min. 21% | 1,13+/- 0,03 | |
Elongation at break | min 1% | ||
Tensile strength | min. 380 N/mm2 | ||
Adherence to dielectric | min. 22 N | ||
Dielectric | Gas injected foamed polyethylene | 4,80 +/- 0,1 | |
Shrinkage max 4 % after 4 hours at 115 ºC | |||
Dielectric constant of base PE 2,25 | |||
Dielectric strength 1of PE 18 kV/mm | |||
PE Oxidative Induction Time | min. 30 minutes / ASTM D 4565 Chapter 17 | ||
PE Oxidative Induction Time | min. 70% after 14 days / 90 ºC | ||
First screen | Tape Aluminium/Polyester/Aluminium | 4,88 +/- 0,13 | |
dielectric - Ovality | max. 0,33 | ||
Tape thickness0.009AL/0.012Pet/0.009AL | |||
Overlapping | min 18% | ||
Second screen | Aluminum alloy braid | 5,48 +/- 0,15 | |
Type 5154A or (5056, 5154, 5954) | |||
Braid construction 16 x 8 x (0,12+0,01/-0,01) | min. 77% | ||
Elongation at break for every wire | min 3% | ||
Tensile strength for every wire | 300N/mm2 | ||
Sheath | PVC - NO BAD ODORS | 6,80 +/-0.15 | |
Sheath color WHITE | Thickness 0,80+/-0.10 mm | ||
Jacket thickness excentricity | max. 43 % | ||
Tensile strength | min .11MPa (TM2) | ||
Tensile strength after 168 H at 80 ºc | +/- 20% (TM2) | ||
Elongation at break | min. 150 % (TM2) | ||
Elongation at break after 168 H at 80 ºC | +/- 20% (TM2) | ||
Spark test | min. 2,5 kVrms | ||
Jacket shrinkage (ANSI/SCTE 88/2003) | max. 10 mm / sample 150 mm |
2. Cable environmental characteristics | ||||
Environmental Space | Indoor | Outdoor | |||
Working temperature | -20 ºC +75 ºC | |||
CPR Cable Classifications | Euro Class Eca | EN50575: 2014+ A1:2016 | ||
Flame Test Listing | vertical flame | IEC 60332-1-2 | ||
UV Resistance per UL 1581, Paragraph 1200 |
Percent Retention of Tensile Strength & Elongation after 720 hours exposure shall be ≥ 80. |
UL2556 |
3- ELECTRICAL CHARACTERISTICS | ||||
3.1 Electrical characteristics - DC and Low frecuency - @ 20 ºC | ||||
Inner conductor resistance | Ohmios /km max. 81 | |||
Outer conductor resistance | Ohmios /km max. 27 | |||
Max. Loop current | Ampers 8 a 20 ºC - 6 a 40 ºC | |||
Dielectric strength | 2 kV D.C. or 1,5 kV A.C. for 1 min. | |||
Insulation resistance | Mohm x km > 10000 Mohm x km | |||
Mutual capacitance | 53±2nF/km | |||
Voltage test of sheath | 2,5 kV A.C. or 3,75 kV D.C. for 1 min. | |||
3.2 Electrical characteristics - High frecuency - @ 20 ºC | ||||
Velocity of propagation | % | 84±2 | ||
Characteristic impedance | Ohmios | 75 +/- 3 | ||
Nominal Delay | nS/m max. | 4,0 | ||
Transfer Impedance | 5-30MHz | ≤15mOhm/m | IEC62153-4-3 | |
Shielding Effectiveness | 30-1000MHz | ≥85dB | IEC62153-4-4 | |
1000-2000MHz | ≥75dB | |||
2000-3000MHz | ≥65dB | |||
Longitudinal attenuation | MHz | dB/100m MAX | ||
50 | 4.30 | |||
100 | 5.20 | |||
200 | 8.40 | |||
470 | 13.40 | |||
800 | 17.00 | |||
1000 | 19.50 | |||
1350 | 23.00 | |||
1750 | 26.20 | |||
2150 | 29.50 | |||
2400 | 31.90 | |||
2700 | 33.60 | |||
3000 | 36.59 | |||
Return Loss | 5 MHz - 470MHz | ≥20dB | ||
470 MHz - 1000MHz | ≥18dB | |||
1000 MHz - 2000MHz | ≥16dB |
Certifications
Product List
Contact Us
Add:No.1058 Jinxi Road,Linglong Industial Zone ,Lin'an City, Zhejiang Province,China.
Tel:+86 571 63761139
Fax:+86 571 63929811
E-mail: amanda@sanyuancable.com.cn
Mobile Phone Version
Sweep into the mobile version
Copyright © 2017 HANGZHOU SANYUAN CABLE CO., LTD. All Rights Reserved Design by: HWAQ